1139087 |
08/03/2024 |
Order Conditions |
The Discharger stated that low UV dosing occurred for two days in August 2024 due to high flow rate testing of the new MBR treatment system. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1139086 |
07/24/2024 |
Order Conditions |
The Discharger violated the UV system operating specification for UV dose contained in the WDRs. The Discharger stated the UV dosing was set below the lower order condition limitation throughout most of July 2024 due to a misunderstanding with the UV dose limitation associated with MBR treatment. The UV dose was increased to a level above the lower order condition limitation on 25 July 2024. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1135470 |
09/30/2023 |
Deficient Monitoring |
Quarterly DOC was not sampled for third quarter because it was a requirement for new permit that went into effect after 3rd quarter sampling was completed. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1135217 |
10/21/2023 |
Late Report |
Annual SMR ( PROGRPT ) (WDR VI.C.7.a) report for 2022 (2915503) was due on 20-OCT-23 |
Violation |
None |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1135216 |
10/21/2023 |
Late Report |
Annual SMR ( PROGRPT ) (WDR VI.C.3.a) report for 2022 (2915509) was due on 20-OCT-23 |
Violation |
None |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1135184 |
10/21/2024 |
Late Report |
Annual SMR ( PROGRPT ) (WDR VI.C.7.a) report for 2023 (2010166) was due on 20-OCT-24 |
Violation |
None |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1135183 |
10/21/2024 |
Late Report |
Annual SMR ( PROGRPT ) (WDR VI.C.3.a) report for 2023 (2010094) was due on 20-OCT-24 |
Violation |
None |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1132936 |
08/14/2024 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 5.8 SU at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131509 |
07/30/2024 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 6.3 SU at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131508 |
07/21/2024 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 6.4 SU at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131507 |
07/20/2024 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 6.4 SU at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131104 |
06/30/2024 |
Order Conditions |
The Discharger violated the UV system operating specification for UV dose contained in the WDRs/NOA. The Discharger stated that they lowered the target dose to 80 mJ/cm2 according to new MBR process guidelines rather than maintaining permit requirement of 100 mJ/cm2. The Discharger increased the target dose back to 105 mJ/cm2 when they realized the permit limit had not been amended. After returning to the higher target dose, the Discharger noted average dose was still dipping below the setpoint and identified several UVI sensors that were causing the dose to be calculated artificially low. The Discharger replaced the faulty sensors in July 2024 and UVI dose calculations are now above the 100 mJ/cm2 permit requirement. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131103 |
05/31/2024 |
Deficient Monitoring |
The Discharger stated the missing temperature results at EFF-002 during May 2024 were due to a miscommunication between the programmable logic controller (PLC) and the supervisory control and data acquisition (SCADA) system. The miscommunication was corrected on 29 May 2024 and EFF-002 temperature monitoring and reporting returned to normal operation. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131102 |
05/31/2024 |
Order Conditions |
The Discharger violated the UV system operating specification for UV dose contained in the WDRs/NOA, as listed in Table C. The Discharger stated that they lowered the target dose to 80 mJ/cm2 according to new MBR process guidelines rather than maintaining permit requirement of 100 mJ/cm2. The Discharger increased the target dose back to 105 mJ/cm2 when they realized the permit limit had not been amended. After returning to the higher target dose, the Discharger noted average dose was still dipping below the setpoint and identified several UVI sensors that were causing the dose to be calculated artificially low. The Discharger replaced the faulty sensors in July 2024 and UVI dose calculations are now above the 100 mJ/cm2 permit requirement. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131101 |
04/30/2024 |
Order Conditions |
The Discharger violated the UV system operating specification for UV dose contained in the WDRs/NOA, as listed in Table C. The Discharger stated that they lowered the target dose to 80 mJ/cm2 according to new MBR process guidelines rather than maintaining permit requirement of 100 mJ/cm2. The Discharger increased the target dose back to 105 mJ/cm2 when they realized the permit limit had not been amended. After returning to the higher target dose, the Discharger noted average dose was still dipping below the setpoint and identified several UVI sensors that were causing the dose to be calculated artificially low. The Discharger replaced the faulty sensors in July 2024 and UVI dose calculations are now above the 100 mJ/cm2 permit requirement. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131100 |
03/31/2024 |
Order Conditions |
The Discharger violated the UV system operating specification for UV dose contained in the WDRs/NOA, as listed in Table C. The Discharger stated that they lowered the target dose to 80 mJ/cm2 according to new MBR process guidelines rather than maintaining permit requirement of 100 mJ/cm2. The Discharger increased the target dose back to 105 mJ/cm2 when they realized the permit limit had not been amended. After returning to the higher target dose, the Discharger noted average dose was still dipping below the setpoint and identified several UVI sensors that were causing the dose to be calculated artificially low. The Discharger replaced the faulty sensors in July 2024 and UVI dose calculations are now above the 100 mJ/cm2 permit requirement. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131099 |
03/19/2024 |
Deficient Monitoring |
The Discharger stated the effluent pH meter would not maintain calibration and was providing inaccurate results from 06 February 2024 through 19 March 2024. A combination of daily and hourly grab samples were collected for pH during this time period. The continuous effluent pH meter probe was replaced on 19 March 2024. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131098 |
02/29/2024 |
Deficient Monitoring |
The Discharger stated the effluent pH meter would not maintain calibration and was providing inaccurate results from 06 February 2024 through 19 March 2024. A combination of daily and hourly grab samples were collected for pH during this time period. The continuous effluent pH meter probe was replaced on 19 March 2024. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131097 |
02/07/2024 |
Deficient Monitoring |
Influent pH not continuously performed |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131095 |
02/29/2024 |
Order Conditions |
The Discharger violated the UV system operating specification for UV dose contained in the WDRs/NOA, as listed in Table C. The Discharger stated that they lowered the target dose to 80 mJ/cm2 according to new MBR process guidelines rather than maintaining permit requirement of 100 mJ/cm2. The Discharger increased the target dose back to 105 mJ/cm2 when they realized the permit limit had not been amended. After returning to the higher target dose, the Discharger noted average dose was still dipping below the setpoint and identified several UVI sensors that were causing the dose to be calculated artificially low. The Discharger replaced the faulty sensors in July 2024 and UVI dose calculations are now above the 100 mJ/cm2 permit requirement. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131094 |
03/06/2024 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 6.2 SU at EFF-001. |
Violation |
None |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131093 |
03/05/2024 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 6.2 SU at EFF-001. |
Violation |
None |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131092 |
03/04/2024 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 6.4 SU at EFF-001. |
Violation |
None |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131091 |
03/01/2024 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 6.2 SU at EFF-001. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131090 |
02/24/2024 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 6.4 SU at EFF-001. |
Violation |
None |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131089 |
02/15/2024 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 6.4 SU at EFF-001. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131088 |
02/06/2024 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 6.4 SU at EFF-001. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131087 |
01/31/2024 |
Deficient Monitoring |
The Discharger stated the missed monthly sampling at INF-001 and EFF-001 in January 2024 was due to a changeover in staffing and an error in the Water Information Management Solution (WIMS) software. The errors were corrected, and monthly sampling was conducted according to the MRP during the subsequent monitoring periods. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131086 |
01/31/2024 |
Deficient Monitoring |
The Discharger stated the missed monthly sampling at INF-001 and EFF-001 in January 2024 was due to a changeover in staffing and an error in the Water Information Management Solution (WIMS) software. The errors were corrected, and monthly sampling was conducted according to the MRP during the subsequent monitoring periods. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1131085 |
01/31/2024 |
Order Conditions |
The Discharger violated the UV system operating specification for UV dose contained in the WDRs/NOA, as listed in Table C. The Discharger stated that they lowered the target dose to 80 mJ/cm2 according to new MBR process guidelines rather than maintaining permit requirement of 100 mJ/cm2. The Discharger increased the target dose back to 105 mJ/cm2 when they realized the permit limit had not been amended. After returning to the higher target dose, the Discharger noted average dose was still dipping below the setpoint and identified several UVI sensors that were causing the dose to be calculated artificially low. The Discharger replaced the faulty sensors in July 2024 and UVI dose calculations are now above the 100 mJ/cm2 permit requirement. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1128632 |
06/02/2024 |
Late Report |
Annual SMR ( PROGRPT ) (WDR VI.C.3.c) report for 2023 (2010133) was due on 01-JUN-24 |
Violation |
None |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1126792 |
03/06/2024 |
CAT2 |
Dichlorobromomethane Monthly Average limit is 1.7 ug/L and reported value was 3.49 ug/L at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1125444 |
02/29/2024 |
CAT1 |
Nitrite Plus Nitrate (as N) Monthly Average limit is 10 mg/L and reported value was 17.7 mg/L at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1125443 |
02/14/2024 |
CAT1 |
Nitrite Plus Nitrate (as N) Weekly Average limit is 16 mg/L and reported value was 17.7 mg/L at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1125442 |
02/03/2024 |
CAT1 |
Total Suspended Solids (TSS) Weekly Average (Mean) limit is 15 mg/L and reported value was 18.2 mg/L at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1125209 |
09/23/2023 |
Deficient Monitoring |
The Discharger stated the ultraviolet (UV) dose and transmittance violations occurred in August 2023 and September 2023 due to issues with the transition to the new UV system. This issue has been resolved and the new UV system is continuously recording UV dose and transmittance |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1125208 |
08/26/2023 |
Deficient Monitoring |
The Discharger stated the ultraviolet (UV) dose and transmittance violations occurred in August 2023 and September 2023 due to issues with the transition to the new UV system. This issue has been resolved and the new UV system is continuously recording UV dose and transmittance. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1125207 |
08/06/2023 |
Deficient Monitoring |
Monitoring and Reporting violations are shown in Table D. The Discharger stated the ultraviolet (UV) dose and transmittance violations occurred in August 2023 and September 2023 due to issues with the transition to the new UV system. This issue has been resolved and the new UV system is continuously recording UV dose and transmittance |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1125206 |
08/15/2023 |
Order Conditions |
The Discharger violated the Filtration System Operating Specifications contained in the WDRs, as listed below. The Discharger stated that the August 2023 turbidity exceedances were caused by the intrusion of sludge into the Surge Basin and ongoing problems with the Decanters. The failed Decanters were removed in September 2023 and Surge Basin cleaning restored the turbidity to levels within the Order Condition limitations. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1125199 |
08/03/2023 |
OEV |
pH Instantaneous Maximum limit is 8.5 SU and reported value was 8.8 SU at EFF-001. |
Violation |
N |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1124692 |
01/26/2024 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1124691 |
01/25/2024 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1124690 |
01/31/2024 |
CAT1 |
Total Suspended Solids (TSS) Monthly Average (Mean) limit is 10 mg/L and reported value was 20.5 mg/L at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1124689 |
01/30/2024 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1124688 |
01/07/2024 |
CAT1 |
Total Suspended Solids (TSS) Weekly Average (Mean) limit is 15 mg/L and reported value was 17.3 mg/L at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1124687 |
01/21/2024 |
CAT1 |
Total Suspended Solids (TSS) Weekly Average (Mean) limit is 15 mg/L and reported value was 22.8 mg/L at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1124686 |
01/31/2024 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 13 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1124685 |
01/28/2024 |
CAT1 |
Total Suspended Solids (TSS) Weekly Average (Mean) limit is 15 mg/L and reported value was 31.1 mg/L at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1124268 |
02/02/2024 |
Late Report |
Annual SMR ( PROGRPT ) (MRP X.D.3) report for 2023 (2010041) was due on 01-FEB-24 |
Violation |
None |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1124267 |
02/02/2024 |
Late Report |
Annual SMR ( MONNPDES ) report for 2023 (2009893) was due on 01-FEB-24 |
Violation |
None |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1124247 |
02/02/2024 |
Late Report |
Annual SMR ( MONNPDES ) report for 2023 (2741197) was due on 01-FEB-24 |
Violation |
None |
Report |
Mountain House WWTP |
453528 |
R5-2023-0033 |
N |
1121844 |
11/02/2023 |
Late Report |
Quarterly SMR ( MONNPDES ) report for Q3 2023 (2705680) was due on 01-NOV-23 |
Violation |
None |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1121618 |
10/21/2023 |
Late Report |
Annual SMR ( PROGRPT ) (WDR VI.C.3.a) report for 2022 (2010093) was due on 20-OCT-23 |
Violation |
None |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1121617 |
10/21/2023 |
Late Report |
Annual SMR ( PROGRPT ) (WDR VI.C.7.a) report for 2022 (2010165) was due on 20-OCT-23 |
Violation |
None |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1120809 |
08/11/2023 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.0 MPN/100 mL at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
453528 |
R5-2023-0033 |
Y |
1120142 |
06/12/2023 |
Order Conditions |
UVT transmittance below 55% (reported at 47%) on 12 June 2023. The Discharger did not provide a suspected cause of the low UV transmittance (UVT) reported value, but UVT values have been consistent and in compliance since the low value recorded on 12 June 2023. |
Violation |
N |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1119772 |
07/19/2023 |
Order Conditions |
Turbidity Daily Maximum limit is 10 NTU and reported value was 12 NTU on 7/17/2023 and 11 NTU on 7/19/2023 at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1119771 |
07/30/2023 |
Order Conditions |
Exceeded average daily turbidity limitation on multiple days in July 2023. The Discharger indicated the turbidity exceedances in were due to complications during replacement of the supervisory control and data acquisition (SCADA) system. The sequencing batch reactor (SBR) decanting and aeration cycle was interrupted by the SCADA system failure. The turbidity issues were resolved when the new SCADA system installation was complete and functioning properly. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1118912 |
06/29/2023 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2 NTU and reported value was 2.5 NTU at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1118911 |
06/28/2023 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2 NTU and reported value was 2.5 NTU at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1117903 |
06/02/2023 |
Late Report |
Annual SMR ( PROGRPT ) (WDR VI.C.3.c) report for 2022 (2010132) was due on 01-JUN-23 |
Violation |
None |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1116207 |
03/31/2023 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 6.2 SU at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1113280 |
02/01/2023 |
Late Report |
Once Only OneTime ( TECHRPT ) (TSO 3.viii) report for 2023/01/31 (2010202) was due on 31-JAN-23 |
Violation |
None |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1112687 |
12/06/2022 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2 NTU and reported value was 2.9 NTU at FIL-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1102734 |
02/09/2022 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 NTU and reported value was 03.08 NTU at FIL-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1102733 |
02/08/2022 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 NTU and reported value was 3.2 NTU at FIL-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1102732 |
02/11/2022 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 JTU and reported value was 2.57 JTU at FIL-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1102731 |
02/07/2022 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 NTU and reported value was 3.4 NTU at FIL-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1102730 |
02/10/2022 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 NTU and reported value was 02.72 NTU at FIL-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
N |
1101299 |
01/20/2022 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1099362 |
12/06/2021 |
OEV |
Total Coliform Instantaneous Maximum limit is 240.0 MPN/100 mL and reported value was 1600.0 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1098281 |
09/23/2021 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 NTU and reported value was 2.59 NTU at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1097218 |
10/01/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 13 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1097215 |
10/06/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.9 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1097214 |
10/05/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 11.2 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1097210 |
10/05/2021 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 NTU and reported value was 2.64 NTU at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1097209 |
10/14/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 3.3 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1097208 |
10/04/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 13.0 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1097206 |
10/02/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 13.0 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1092737 |
06/23/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.2 MPN/100 mL at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1092731 |
06/24/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.9 MPN/100 mL at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1092730 |
06/25/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.2 MPN/100 mL at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1092729 |
06/22/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 3.3 MPN/100 mL at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1092250 |
03/04/2021 |
Deficient Monitoring |
The Discharger indicated missing UV Dose data between 4 March 2021 and 10 March 2021 was due to a failure of the human machine interface (HMI) panel. The issue was resolved on 10 March 2021 by the Facility¿s SCADA contractor. |
Violation |
N |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1092249 |
02/28/2021 |
Deficient Monitoring |
The Discharger failed to conduct Emergency Storage Basin monitoring for wastewater diversions to the basins in February 2021. The Discharger indicated staff have been reminded regarding the monitoring requirements contained in the MRP when wastewater is diverted to the Emergency Storage Basins. |
Violation |
N |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1092248 |
03/31/2021 |
CAT1 |
Ammonia, Total (as N) Monthly Average limit is 0.80 mg/L and reported value was 0.85 mg/L at EFF-001. |
Violation |
N |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1091510 |
05/31/2021 |
CAT1 |
Ammonia, Total (as N) Monthly Average (Mean) limit is 0.80 % and reported value was 00.848 % at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1089650 |
03/16/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.8 MPN/100 mL at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1089649 |
03/03/2021 |
CAT1 |
Ammonia, Total (as N) Weekly Average limit is 1.7 mg/L and reported value was 01.84 mg/L at EFF-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1085819 |
12/21/2020 |
Order Conditions |
Daily average UV transmittance fell below the required amount of >/= 55% on 12/21/2020 and 12/22/2020 (recorded at 34% and 49% respecively) |
Violation |
N |
Report |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1084617 |
12/21/2020 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 3.3 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1084616 |
12/17/2020 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1084615 |
12/24/2020 |
Deficient Monitoring |
Sample was taken (effluent BOD) and the lab signed for, but did not place sample bottle in their cooler. They left it in the refrigerator. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1084614 |
12/24/2020 |
Deficient Monitoring |
Sample was taken (effluent TSS) and the lab signed for, but did not place sample bottle in their cooler. They left it in the refrigerator. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1081816 |
10/02/2020 |
Order Conditions |
The 1/4" tube that fed the UVT meter sprung a seep and the inside of the UVT meter got water in it causing the couvette to fog up. You could clean the couvette and the UVT would go back up to >70%, but that only lasted until the couvette fogged up again. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1080885 |
09/22/2020 |
OEV |
Total Coliform Not to exceed a specific limit more than once within any 30-day period. limit is 23 MPN/100 mL and reported value was 49 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1080884 |
09/21/2020 |
OEV |
Total Coliform Not to exceed a specific limit more than once within any 30-day period. limit is 23 MPN/100 mL and reported value was 33 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1080883 |
09/08/2020 |
OEV |
Total Coliform Daily Maximum limit is 240 MPN/100 mL and reported value was 540 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1078792 |
07/10/2020 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1078791 |
07/09/2020 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1078790 |
07/08/2020 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
1078787 |
07/13/2020 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
Violation |
N |
eSMR |
Mountain House WWTP |
416414 |
R5-2017-0119 |
Y |
Report defaults to display violations within the last year. Click here to see last five years of violations. Refer to the Interactive Violation Report for more data.
|