Violation ID |
Occurrence Date |
Violation Type |
Violation Description(-) |
Violation Status |
Priority |
Source |
Facility Name |
Violated Reg. Meas. ID |
Violated Reg. Meas. Order No. |
Linked to Enf. |
1126132 |
02/28/2024 |
Order Conditions |
Violation 6 - During the 28 February 2024 inspection of the Facility, Central Valley Water Board staff observed the Poly Urea Process Building, which is located in an area that was not paved when the WDRs were issued in 2010. Additionally, Poly Urea processing is not included as a treatment process in the 2010 WDRs. |
Violation |
None |
Inspection |
Thunderbolt Wood Treating Class II Surface Impoundment |
377017 |
R5-2010-0125 |
Y |
1126131 |
02/28/2024 |
Order Conditions |
Violation 5 - During the 28 February 2024 inspection of the Facility, Central Valley Water Board staff observed the Sump 1 discharge pipe disconnect from the pipe that is used to transfer leachate from Sump 1 to the Class II surface impoundment. Discharge from the Sump 1 pipe can now flow to an adjacent offsite property. |
Violation |
None |
Inspection |
Thunderbolt Wood Treating Class II Surface Impoundment |
377017 |
R5-2010-0125 |
Y |
1126130 |
02/28/2024 |
Order Conditions |
Violation 4 - During the 28 February 2024 inspection of the Facility, as well as in multiple Facility status updates submitted to Central Valley Water Board staff since January 2024, the Discharger has stated that no treated stormwater leachate has been discharged to the City of Riverbank?s wastewater treatment system. |
Violation |
None |
Inspection |
Thunderbolt Wood Treating Class II Surface Impoundment |
377017 |
R5-2010-0125 |
Y |
1126129 |
02/28/2024 |
Order Conditions |
Violation 3 - During the 28 February 2024 inspection of the Facility, Central Valley Water Board staff observed only about two feet of freeboard in the Facility?s Surface Impoundment |
Violation |
None |
Inspection |
Thunderbolt Wood Treating Class II Surface Impoundment |
377017 |
R5-2010-0125 |
Y |
1126128 |
02/28/2024 |
Order Conditions |
Violation 2 - During the 28 February 2024 inspection of the Facility, Central Valley Water Board staff observed ponded contact stormwater (i.e. leachate) across almost the entire CCA/ACZA diversionary structure and the expanded CCA/ACZA diversionary structure. |
Violation |
None |
Inspection |
Thunderbolt Wood Treating Class II Surface Impoundment |
377017 |
R5-2010-0125 |
Y |
1126127 |
02/28/2024 |
Order Conditions |
Violation 1 - During the 28 February 2024 inspection of the Facility, Central Valley Water Board staff observed ponded contact stormwater (i.e. leachate) across almost the entire southern portion of the treated wood storage area, within the Facility?s precipitation and drainage control system. |
Violation |
None |
Inspection |
Thunderbolt Wood Treating Class II Surface Impoundment |
377017 |
R5-2010-0125 |
Y |
1124889 |
03/06/2024 |
Order Conditions |
Provision E.7 and E.8, continued VOCs and inorganic exceedances in groundwater. |
Violation |
None |
Report |
28Th Street LF |
132763 |
R5-2004-0039 |
N |
1124176 |
02/06/2024 |
Order Conditions |
GW continues to be affected by LFG migrating from unit. |
Violation |
None |
Report |
Dellar Landfill |
400800 |
R5-2015-0051 |
N |
1119972 |
09/12/2023 |
Order Conditions |
Monitoring report lacked proper transmittal letter certifying report by responsible party |
Violation |
None |
Report |
Jackson Road LF Closure |
132375 |
R5-2003-0075 |
N |
1119870 |
09/07/2023 |
Order Conditions |
VOCs and inorganic compounds continue to be detected above concentration limits in GW |
Violation |
None |
Report |
Florin-Perkins LF |
391050 |
R5-2013-0042 |
N |
1118684 |
06/30/2023 |
Order Conditions |
LFG detected in vadose zone outside of WMU. Leachate sumps reported over 30 centimeters of liquids in December 2022 |
Violation |
None |
Report |
Foothill Sanitary LF |
400805 |
R5-2015-0058 |
N |
1118368 |
07/11/2023 |
Order Conditions |
LFG has migrated outside of the WMU. This condition is ongoing and should be addressed by enhancing the LFG system |
Violation |
None |
Report |
North Cnty Recycling Center and Sanitary LF |
373222 |
R5-2010-0016 |
N |
Report defaults to display violations within the last year. Click here to see last five years of violations. Refer to the Interactive Violation Report for more data.
|