Welcome to California
 California Home
Welcome to California - images of Golden Gate Bridge, ocean sunset, waterfall, flowers, and city skyline California Home Welcome to the California Environmental Protection Agency
 California Integrated Water Quality System Project (CIWQS)
   Facility At-A-Glance Report

  
   [VIEW PRINTER FRIENDLY VERSION] [EXPORT THIS REPORT TO EXCEL]

  
   SEARCH CRITERIA:      [REFINE SEARCH] [NEW SEARCH] [GLOSSARY]
Place ID S845197
  
  
  
  
Hide All Show All
General Information
Region Place ID Place Name Place Type Place Address Place County
4 S845197 Sun Lite Metals Facility 2210 East 85th Street Los Angeles, CA, 90001 Los Angeles

Expand/Contract Related Parties
Related Parties
Party Party Type Party Name Role Classification Relationship Start Date Relationship End Date
S640548 Organization YONG SING US INC N/A Private Business 03/09/2016
Total Related Parties: 1

Expand/Contract Regulatory Measures
Regulatory Measures
Reg Measure ID Reg Measure Type Region Program Order No. WDID Effective Date Expiration Date Status Amended?
S470451 Industrial 4 INDSTW 2014-0057-DWQ 4 19I026498 03/17/2016 Active
Total Reg Measures: 1

Expand/Contract Violations
Violations
Violation ID Occurred Date Violation Type (-) Violation Description Corrective Action Status Classification Source
S888799 01/05/2024 Incomplete/Insufficient SWPPP SWPPP uploaded in SMARTS on 4/29/2020 does not include a facility map, and map uploaded in SMARTS on 3/16/2016 does not show surface water flow direction along the western side of the facility The list of significant materials handled onsite does not include recycling used tires and how butane tanks and other cylinders are handled onsite. The Permittee has not collected/analyzed a stormwater sample during the following fiscal years: 2022-2023, 2021-2022, 2020-2021, 2019-2020, 2018-2019, 2017-2018, 2016-2017, and 2015-2016. Violation B Inspection
S888800 01/05/2024 Deficient BMP Implementation Residual metal debris was observed on sidewalks. The surface ground of the facility’s northern wall had a large quantity of scrap materials and debris without BMPs in place. In addition, the concrete berm in this area was broken/damaged. 55-gallon metal drums containing oils were stored indoors without containment. A concrete berm along the entire perimeter of the facility was installed to retain discharges and stormwater runoff onsite, but the concrete berm was broken and damaged in various areas of the facility, and the eastern side of the berm was not accessible during the inspection. Two non-working heavy equipment were stored outdoors and leaking oils onto the ground without BMPs in place. Two tote tanks containing hazardous wastes were stored outdoors by the outward sloping without covers or secondary containment. Scrap metal/materials/used tires were stored on the ground without BMPs in place. Oil spills were observed onsite without BMPs in place. Multiple oil containers of various sizes were stored outdoors without covers or secondary containment. Violation S Inspection
Report displays most recent five years of violations. Refer to the Interactive Violation Report for more data.
Total Violations: 2 Priority Violations: 0
*Click the "(+/-) Violation Description" link to expand and contract the violation description.
*As of 5/20/2010, the Water Board's Enforcement Policy requires that all violations be classified as 1, 2 or 3, with class 1 being the highest. Prior to this, violations were simply classified as Yes or No. If a 123 classification has been assigned to a violation that occurred before this date, that classification data will be displayed instead of the Yes/No data.

Violation Types
Deficient BMP Implementation = Deficient BMP Implementation Incomplete/Insufficient SWPPP = Incomplete/Insufficient SWPPP

Expand/Contract Enforcement Actions
Enforcement Actions
Enf Id Enf Type Enf Order No. Effective Date Status
S453127 Notice of Violation 03/20/2024 Active
S429379 Notice of Violation 03/08/2018 Historical
S426269 Notice to Comply 07/12/2017 Historical
Total Enf Actions: 3

Expand/Contract Inspections
Inspections
Inspection ID Inspection Type Lead Inspector Actual End Date Planned Violations Attachment
S2064109 Enforcement Follow-up Luz Vargas 02/20/2024 N 0 N/A
S2063237 B Type compliance Luz Vargas 01/05/2024 N 2 N/A
S2034406 B Type compliance Sean Lee 07/12/2017 N 0 N/A
S2030110 B Type compliance Orlando Gonzalez 06/09/2016 N 0 N/A
Total Inspections: 4 Last Inspection: 02/20/2024
  
The current report was generated with data as of: 05/17/2024
Regional Boards are in the process of entering backlogged data.
As a result, data may be incomplete.
Back to Main Page  |  Back to Top of Page