Facility At-A-Glance Report |
|
|
[VIEW PRINTER FRIENDLY VERSION]
[EXPORT THIS REPORT TO EXCEL]
|
|
|
[REFINE SEARCH]
[NEW SEARCH]
[GLOSSARY]
Place ID 646825
|
|
|
|
|
|
General Information
|
Region |
Place ID |
Place Name |
Place Type |
Place Address |
Place County |
2 |
646825 |
Hanson Aggregates SF Pier 92 Sand Yard |
Sand and Gravel Mining |
480 Amador San Francisco, CA, 94124 |
San Francisco |
|
|
Related Parties
|
|
Total Related Parties: 3
|
|
|
Regulatory Measures
|
|
Total Reg Measures: 3
|
|
|
Violations
|
Violation ID |
Occurred Date |
Violation Type |
(-) Violation Description |
Corrective Action |
Status |
Classification |
Source |
1117595 |
05/26/2023 |
OEV |
Turbidity Maximum Daily (MDEL) limit is 50 NTU and reported value was 110 NTU. |
"In response to the exceedance, we conducted an investigation at the site and found that the probable cause of this exceedance was an unusual volume of fine particles in the flow stream that did not allow for enough settling time. As a corrective action, the facility will add a turbidity curtain at the last settling pond and as necessary in the other ponds." |
Violation |
B |
Report |
1120016 |
12/31/2022 |
UAUTHDISC |
According to the discharger's 5-day report, the discharge was not directly observed, but likely occurred on December 31, 2022, due to a major storm event. The discharge was likely composed of comingled stormwater and potable water and discharged directly to the San Francisco Bay. From the report, "storm
water flows breached the storm water retention berm, and the flow at this location caused a potable water line to break. Potable water then combined with accumulated storm water and breached a second of the Facility’s storm water retention berms; this comingled potable and storm water is believed to have discharged off-site." |
According to the report, the water main was shut off by a neighbor. The discharger reported that it repaired the damaged storm water retention berms and augmented its holding capacity by building the berms longer and higher. It also added retention berms throughout the site. The potable water line was repaired, and will be moved to a more protected area by January 13, 2023. |
Violation |
B |
Report |
1075519 |
03/17/2020 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 0.0 mg/L and reported value was 0.1 mg/L. |
|
Violation |
B |
Report |
Report displays most recent five years of violations. Refer to the Interactive Violation Report for more data.
|
|
Total Violations: 3
|
Priority Violations: 0
|
*Click the "(+/-) Violation Description" link to expand and contract the violation description.
*As of 5/20/2010, the Water Board's Enforcement Policy requires that all violations be classified as 1, 2 or 3, with class 1 being the highest. Prior to this, violations were simply classified as Yes or No. If a 123 classification has been assigned to a violation that occurred before this date, that classification data will be displayed instead of the Yes/No data.
|
Violation Types |
CAT2 = Category 2 Pollutant (Effluent Violation for Group 2 Pollutant)
|
OEV = Other Effluent Violation
|
UAUTHDISC = Unauthorized Discharge
|
|
|
|
Enforcement Actions
|
Enf Id |
Enf Type |
Enf Order No. |
Effective Date |
Status |
452939 |
Oral Communication |
|
05/31/2023 |
Historical |
454313 |
Oral Communication |
|
01/09/2023 |
Historical |
439566 |
Admin Civil Liability |
R2-2020-1033 |
11/11/2020 |
Historical |
428800 |
Admin Civil Liability |
R2-2019-1010 |
05/16/2019 |
Historical |
425302 |
Staff Enforcement Letter |
|
09/27/2018 |
Historical |
394960 |
Admin Civil Liability |
R2-2014-1014 |
05/29/2014 |
Historical |
311941 |
Notice of Violation |
NOV |
08/31/2006 |
Historical |
374260 |
Admin Civil Liability |
R2-2011-0092 |
08/31/2006 |
Historical |
252966 |
Admin Civil Liability |
R2-2004-0051 |
09/15/2004 |
Historical |
249436 |
Admin Civil Liability |
R2-2002-0034 |
05/22/2002 |
Withdrawn |
242357 |
Admin Civil Liability |
R2-2002-0034 |
05/22/2002 |
Historical |
238368 |
Oral Communication |
|
10/30/2001 |
Historical |
|
Total Enf Actions: 12
|
|
|
Inspections
|
|
Total Inspections: 4 |
Last Inspection: 03/02/2018 |
|
|
|
|
|
The current report was generated with data as of: 07/16/2024
Regional Boards are in the process of entering backlogged data.
As a result, data may be incomplete.
|
|
Back to Main Page
|