Place ID 631581
|
|
| |
|
|
| |
|
General Information
|
| Region |
Place ID |
Place Name |
Place Type |
Place Address |
Place County |
| 9 |
631581 |
Padre Dam CS |
Collection_System |
9300 Fanita Santee, CA, 92071 |
San Diego |
|
|
Related Parties
|
|
|
Total Related Parties: 14
|
|
|
Regulatory Measures
|
|
|
Total Reg Measures: 2
|
|
|
Violations
|
| Violation ID |
Occurred Date |
Violation Type |
(-) Violation Description |
Corrective Action |
Status |
Classification |
Source |
| 1150394 |
01/01/2026 |
SSOS |
Type: Category 1 Spill; Flow Exceeded Capacity (Separate Collection System Only),Other (specify below) caused 1640 gallons of sewage to spill from Other Sewer System Structure at Fanita Parkway SSO (9300) to Drainage Conveyance System that discharges to surface water,Unpaved Surface,Surface Water |
Repaired Facilities or Replaced Defect,Other (specify below). Replaced the vault lid with a more robust steel lid and also changed out the ripped gasket. Systems staff were directed to divert all flow during future forecasted heavy precipitation. Will review heavy storm procedures and when to divert flow at sewer diversions in the next System Operations Meeting. |
Violation |
A |
SSO |
| 1133611 |
09/20/2023 |
SSOS |
Type: Category 1 Spill; Debris-wipes/Non-disposables, Fats, Oil and Grease (FOG), Other (specify below) caused 12900 gallons of sewage to spill from Inside Building or Structure, Manhole at Greenfield Dr SSO (204) to Building or Structure, Drainage Conveyance System, Paved Surface |
Inspected Sewer Using CCTV to Determine Cause, Other (specify below). Communication department to send out reminders of the importance of keeping wipes and FOG out of the Sanitary Sewer System. SmartCover monitoring device to be installed in nearby, upstream manhole from spill location. Maintenance staff to document manhole rung condition and provide to supervisor to plan for removal of rungs that are deteriorating. |
Violation |
B |
SSO |
|
Report displays most recent five years of violations. Refer to the Interactive Violation Report for more data.
|
|
|
Total Violations: 2
|
Priority Violations: 0
|
*Click the "(+/-) Violation Description" link to expand and contract the violation description.
*As of 5/20/2010, the Water Board's Enforcement Policy requires that all violations be classified as 1, 2 or 3, with class 1 being the highest. Prior to this, violations were simply classified as Yes or No. If a 123 classification has been assigned to a violation that occurred before this date, that classification data will be displayed instead of the Yes/No data.
|
| Violation Types |
|
SSOS = Sanitary Sewer Overflow/Spill/
|
|
|
|
Enforcement Actions
|
| Enf Id |
Enf Type |
Enf Order No. |
Effective Date |
Status |
| 432873 |
13267 Letter |
R9-2019-0014 |
06/12/2019 |
Active |
| 377600 |
Staff Enforcement Letter |
|
02/22/2011 |
Historical |
| 372219 |
Staff Enforcement Letter |
|
12/15/2009 |
Historical |
| 251757 |
Staff Enforcement Letter |
|
03/17/2004 |
Historical |
| 250260 |
Notice of Violation |
R9-2003-428 |
12/16/2003 |
Historical |
| 243044 |
Staff Enforcement Letter |
|
07/24/2003 |
Historical |
| 242764 |
13267 Letter |
|
02/13/2002 |
Historical |
| 242763 |
Notice of Violation |
|
02/13/2002 |
Historical |
| 234751 |
Staff Enforcement Letter |
|
05/30/2000 |
Historical |
| 223623 |
Admin Civil Liability |
R9-1999-0045 |
06/26/1996 |
Historical |
|
|
Total Enf Actions: 10
|
|
|
Inspections
|
|