Violations
|
| Violation ID |
Occurred Date |
Violation Type |
(-) Violation Description |
Corrective Action |
Status |
Classification |
Source |
| 1150927 |
02/01/2026 |
SSOS |
Type: Category 1 Spill; Pipe Structural Problem/Failure - Installation,Debris-General caused 40 gallons of sewage to spill from Gravity Mainline at Intersection of Carter Street and Fir Avenue to Street/Curb and Gutter (2 3),Paved Surface,Drainage Conveyance System that discharges to surface water |
Plan Rehabilitation or Replacement of Sewer,Post Spill CCTV. Post spill CCTV inspection revealed a moderate offset within what appeared to be a repair job on the four-inch vitrified clay pipe. It has been rumored that a contractor who was awarded a past storm drain improvement project broke this section of sewer mainline and said they did a poor job at making the repairs. Because of the expensive costs to pave asphalt, being more expensive than installing sewer pipe, along with the district's aging sewer infrastructure, the District continues to apply for funding to rehabilitated all potions of the system. This basin (Willow Basin) has roughly 30% design completed. Unfortunately there has been a lack of available funding from the State or the federal government, even for severely disadvantaged communities such as the Tuolumne township. The blockage was reported as a soft block that accumulated at the off-set. No amount enhanced cleaning schedule can reasonably be expected to prevent the spill from reoccurring. The pipe needs to be repaired. |
Violation |
A |
SSO |
| 1144710 |
05/07/2025 |
SSOS |
Type: Category 1 Spill; Pipe Structural Problem/Failure - Controls,Root Intrusion caused 1980 gallons of sewage to spill from Gravity Mainline at Manhole A10 to Drainage Conveyance System |
Inspected Sewer Using CCTV to Determine Cause,Post Spill CCTV,Adjusted Schedule/Method of Preventive Maintenance,Plan Rehabilitation or Replacement of Sewer. The sewer segment has been placed on a bi-annual maintenance schedule. It will remain on this schedule until the District can repair the failed portion of the pipe. |
Violation |
A |
SSO |
| 1138795 |
01/02/2025 |
SSOS |
Type: Category 1 Spill; Inappropriate Discharge to Collection System,Debris-General,Debris from Lateral caused 278 gallons of sewage to spill from Gravity Mainline,Lateral Clean Out (Private) at Funeral Home Alley to Drainage Conveyance System,Unpaved Surface,Drainage Conveyance System that discharges to surface water,Paved Surface |
Plan Rehabilitation or Replacement of Sewer,Other (specify below). The property owners advised the District that they had a plumber out a week prior to clear their private lateral. The lateral is known to be defective due to a lack of adequate slope, meaning general sewer debris settles out in the lateral causing a blockage. The District believes the lumber pushed the lateral blockage into the sewer mainline. Being at the end of the mainline with a corresponding minimum flow, the debris did not convey through the collection system and caused the mainline blockage. |
Violation |
A |
SSO |
|
Report displays most recent five years of violations. Refer to the Interactive Violation Report for more data.
|
|
|
Total Violations: 3
|
Priority Violations: 0
|
*Click the "(+/-) Violation Description" link to expand and contract the violation description.
*As of 5/20/2010, the Water Board's Enforcement Policy requires that all violations be classified as 1, 2 or 3, with class 1 being the highest. Prior to this, violations were simply classified as Yes or No. If a 123 classification has been assigned to a violation that occurred before this date, that classification data will be displayed instead of the Yes/No data.
|