Violation ID |
Occurred Date |
Violation Type |
(-) Violation Description |
Corrective Action |
Status |
Classification |
Source |
1126792 |
03/06/2024 |
CAT2 |
Dichlorobromomethane Monthly Average limit is 1.7 ug/L and reported value was 3.49 ug/L at EFF-001. |
Staff is investigating root cause of exceedance and will report on findings in subsequent report. |
Violation |
U |
eSMR |
1125444 |
02/29/2024 |
CAT1 |
Nitrite Plus Nitrate (as N) Monthly Average limit is 10 mg/L and reported value was 17.7 mg/L at EFF-001. |
High nitrite+nitrate (as N) levels will be within permit limits once MBR process is fully implemented. |
Violation |
U |
eSMR |
1125443 |
02/14/2024 |
CAT1 |
Nitrite Plus Nitrate (as N) Weekly Average limit is 16 mg/L and reported value was 17.7 mg/L at EFF-001. |
High nitrite+nitrate (as N) levels will be within permit limits once MBR process is fully implemented. |
Violation |
U |
eSMR |
1125442 |
02/03/2024 |
CAT1 |
Total Suspended Solids (TSS) Weekly Average (Mean) limit is 15 mg/L and reported value was 18.2 mg/L at EFF-001. |
Transition to MBR process only eliminated high TSS concentrations. |
Violation |
U |
eSMR |
1124267 |
02/02/2024 |
LREP |
Annual SMR ( MONNPDES ) report for 2023 (2009893) was due on 01-FEB-24 |
|
Violation |
B |
Report |
1124247 |
02/02/2024 |
LREP |
Annual SMR ( MONNPDES ) report for 2023 (2741197) was due on 01-FEB-24 |
|
Violation |
B |
Report |
1124268 |
02/02/2024 |
LREP |
Annual SMR ( PROGRPT ) (MRP X.D.3) report for 2023 (2010041) was due on 01-FEB-24 |
|
Violation |
B |
Report |
1124686 |
01/31/2024 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 13 MPN/100 mL at UVS-001. |
MBR process online |
Violation |
U |
eSMR |
1124690 |
01/31/2024 |
CAT1 |
Total Suspended Solids (TSS) Monthly Average (Mean) limit is 10 mg/L and reported value was 20.5 mg/L at EFF-001. |
MBR process online |
Violation |
U |
eSMR |
1124689 |
01/30/2024 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
MBR process online |
Violation |
U |
eSMR |
1124685 |
01/27/2024 |
CAT1 |
Total Suspended Solids (TSS) Weekly Average (Mean) limit is 15 mg/L and reported value was 31.1 mg/L at EFF-001. |
MBR process online |
Violation |
U |
eSMR |
1124692 |
01/26/2024 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
MBR process online |
Violation |
U |
eSMR |
1124691 |
01/25/2024 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
MBR process online |
Violation |
U |
eSMR |
1124687 |
01/20/2024 |
CAT1 |
Total Suspended Solids (TSS) Weekly Average (Mean) limit is 15 mg/L and reported value was 22.8 mg/L at EFF-001. |
MBR process online |
Violation |
U |
eSMR |
1124688 |
01/06/2024 |
CAT1 |
Total Suspended Solids (TSS) Weekly Average (Mean) limit is 15 mg/L and reported value was 17.3 mg/L at EFF-001. |
MBR process online |
Violation |
U |
eSMR |
1121844 |
11/02/2023 |
LREP |
Quarterly SMR ( MONNPDES ) report for Q3 2023 (2705680) was due on 01-NOV-23 |
|
Violation |
B |
Report |
1121617 |
10/21/2023 |
LREP |
Annual SMR ( PROGRPT ) (WDR VI.C.7.a) report for 2022 (2010165) was due on 20-OCT-23 |
|
Violation |
B |
Report |
1121618 |
10/21/2023 |
LREP |
Annual SMR ( PROGRPT ) (WDR VI.C.3.a) report for 2022 (2010093) was due on 20-OCT-23 |
|
Violation |
B |
Report |
1125209 |
09/23/2023 |
DMON |
The Discharger stated the ultraviolet (UV) dose and transmittance violations occurred in August 2023 and September 2023 due to issues with the transition to the new UV system. This issue has been resolved and the new UV system is continuously recording UV dose and transmittance |
|
Violation |
B |
Report |
1125208 |
08/26/2023 |
DMON |
The Discharger stated the ultraviolet (UV) dose and transmittance violations occurred in August 2023 and September 2023 due to issues with the transition to the new UV system. This issue has been resolved and the new UV system is continuously recording UV dose and transmittance. |
|
Violation |
B |
Report |
1125206 |
08/15/2023 |
Order Conditions |
The Discharger violated the Filtration System Operating Specifications contained in the WDRs, as listed below. The Discharger stated that the August 2023 turbidity exceedances were caused by the intrusion of sludge into the Surge Basin and ongoing problems with the Decanters. The failed Decanters were removed in September 2023 and Surge Basin cleaning restored the turbidity to levels within the Order Condition limitations. |
|
Violation |
B |
Report |
1120809 |
08/11/2023 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.0 MPN/100 mL at EFF-001. |
Cleaned the surge basin |
Violation |
B |
eSMR |
1125207 |
08/06/2023 |
DMON |
Monitoring and Reporting violations are shown in Table D. The Discharger stated the ultraviolet (UV) dose and transmittance violations occurred in August 2023 and September 2023 due to issues with the transition to the new UV system. This issue has been resolved and the new UV system is continuously recording UV dose and transmittance |
|
Violation |
B |
Report |
1125199 |
08/03/2023 |
OEV |
pH Instantaneous Maximum limit is 8.5 SU and reported value was 8.8 SU at EFF-001. |
The Discharger stated that the effluent pH sensor has been malfunctioning and several instantaneous high pH values have been recorded that do not indicate true effluent pH. However, the effluent pH exceedance on 3 August 2023 lasted longer than the other high pH readings during the month and could not be positively attributed to a malfunctioning pH sensor. A new primary pH sensor has been installed and a backup pH sensor is stored on site. |
Violation |
B |
Report |
1119771 |
07/30/2023 |
Order Conditions |
Exceeded average daily turbidity limitation on multiple days in July 2023. The Discharger indicated the turbidity exceedances in were due to complications during replacement of the supervisory control and data acquisition (SCADA) system. The sequencing batch reactor (SBR) decanting and aeration cycle was interrupted by the SCADA system failure. The turbidity issues were resolved when the new SCADA system installation was complete and functioning properly. |
Removed fuse so the valve cannot open again. |
Violation |
B |
eSMR |
1119772 |
07/19/2023 |
Order Conditions |
Turbidity Daily Maximum limit is 10 NTU and reported value was 12 NTU on 7/17/2023 and 11 NTU on 7/19/2023 at UVS-001. |
Same as previous Turbidity violation for Jule |
Violation |
B |
eSMR |
1118912 |
06/29/2023 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2 NTU and reported value was 2.5 NTU at EFF-001. |
Reduced the sludge flow rate to the centrifuge. |
Violation |
B |
eSMR |
1118911 |
06/28/2023 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2 NTU and reported value was 2.5 NTU at EFF-001. |
Reduced sludge flow rate to the centrifuge. |
Violation |
B |
eSMR |
1120142 |
06/12/2023 |
Order Conditions |
UVT transmittance below 55% (reported at 47%) on 12 June 2023. The Discharger did not provide a suspected cause of the low UV transmittance (UVT) reported value, but UVT values have been consistent and in compliance since the low value recorded on 12 June 2023. |
|
Violation |
B |
Report |
1117903 |
06/02/2023 |
LREP |
Annual SMR ( PROGRPT ) (WDR VI.C.3.c) report for 2022 (2010132) was due on 01-JUN-23 |
|
Violation |
B |
Report |
1116207 |
03/31/2023 |
OEV |
pH Instantaneous Minimum limit is 6.5 SU and reported value was 6.2 SU at EFF-001. |
Clean the pH probe more often. |
Violation |
B |
eSMR |
1113280 |
02/01/2023 |
LREP |
Once Only OneTime ( TECHRPT ) (TSO 3.viii) report for 2023/01/31 (2010202) was due on 31-JAN-23 |
|
Violation |
B |
Report |
1112687 |
12/06/2022 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2 NTU and reported value was 2.9 NTU at FIL-001. |
Replaced with a new pump and cleaned surge basin |
Violation |
B |
eSMR |
1102732 |
02/11/2022 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 JTU and reported value was 2.57 JTU at FIL-001. |
We switched to another decant valve and hose to fix the problem. The filter channel was cleaned to remove solids from the surge basin. |
Violation |
B |
eSMR |
1102730 |
02/10/2022 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 NTU and reported value was 02.72 NTU at FIL-001. |
We switched to another decant valve and hose to fix the problem. The filter channel was cleaned to remove solids from the surge basin. |
Violation |
B |
eSMR |
1102734 |
02/09/2022 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 NTU and reported value was 03.08 NTU at FIL-001. |
We switched to another decant valve and hose to fix the problem. The filter channel was cleaned to remove solids from the surge basin. |
Violation |
B |
eSMR |
1102733 |
02/08/2022 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 NTU and reported value was 3.2 NTU at FIL-001. |
We switched to another decant valve and hose to fix the problem. The filter channel was cleaned to remove solids from the surge basin. |
Violation |
B |
eSMR |
1102731 |
02/07/2022 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 NTU and reported value was 3.4 NTU at FIL-001. |
We switched to another decant valve and hose to fix the problem. The filter channel was cleaned to remove solids from the surge basin. |
Violation |
B |
eSMR |
1101299 |
01/20/2022 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
We switched to a different decanter hose and did an 8-hour thorough cleaning of the surge basin which corrected the problem.
|
Violation |
B |
eSMR |
1099362 |
12/06/2021 |
OEV |
Total Coliform Instantaneous Maximum limit is 240.0 MPN/100 mL and reported value was 1600.0 MPN/100 mL at UVS-001. |
At present UV system is running in manual mode until the contractor¿s repair (Auto restart and Low-level Alarm) |
Violation |
B |
eSMR |
1097209 |
10/14/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 3.3 MPN/100 mL at UVS-001. |
Operators are trying to optimize the process to avoid the violation
|
Violation |
B |
eSMR |
1097215 |
10/06/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.9 MPN/100 mL at UVS-001. |
Operators are trying to optimize the process to avoid the violation
|
Violation |
B |
eSMR |
1097210 |
10/05/2021 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 NTU and reported value was 2.64 NTU at UVS-001. |
Operators are trying to optimize the process to avoid the violation
|
Violation |
B |
eSMR |
1097214 |
10/05/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 11.2 MPN/100 mL at UVS-001. |
Operators are trying to optimize the process to avoid the violation
|
Violation |
B |
eSMR |
1097208 |
10/04/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 13.0 MPN/100 mL at UVS-001. |
Operators are trying to optimize the process to avoid the violation
|
Violation |
B |
eSMR |
1097206 |
10/02/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 13.0 MPN/100 mL at UVS-001. |
Operators are trying to optimize the process to avoid the violation |
Violation |
B |
eSMR |
1097218 |
10/01/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 13 MPN/100 mL at UVS-001. |
Operators are trying to optimize the process to avoid the violation |
Violation |
B |
eSMR |
1098281 |
09/23/2021 |
Order Conditions |
Turbidity Daily Average (Mean) limit is 2.0 NTU and reported value was 2.59 NTU at UVS-001. |
Operation is trying to optimize the process. |
Violation |
B |
eSMR |
1092730 |
06/25/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.2 MPN/100 mL at EFF-001. |
Settled solids in the surge basin are being removed by the trailer-mounted pump. |
Violation |
B |
eSMR |
1092731 |
06/24/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.9 MPN/100 mL at EFF-001. |
Settled solids in the surge basin are being removed by the trailer-mounted pump. |
Violation |
B |
eSMR |
1092737 |
06/23/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.2 MPN/100 mL at EFF-001. |
Settled solids in the surge basin are being removed by the trailer-mounted pump. |
Violation |
B |
eSMR |
1092729 |
06/22/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 3.3 MPN/100 mL at EFF-001. |
Settled solids in the surge basin are being removed by the trailer-mounted pump. |
Violation |
B |
eSMR |
1091510 |
05/31/2021 |
CAT1 |
Ammonia, Total (as N) Monthly Average (Mean) limit is 0.80 % and reported value was 00.848 % at EFF-001. |
The mixed liquor TSS was increased to ensure adequate treatment for Ammonia. |
Violation |
B |
eSMR |
1092248 |
03/31/2021 |
CAT1 |
Ammonia, Total (as N) Monthly Average limit is 0.80 mg/L and reported value was 0.85 mg/L at EFF-001. |
The Discharger indicated the ammonia violation was due to incorrect sludge wasting. The issue was resolved by decreasing the wasting rate to increase the mixed liquor suspended solids (MLSS). |
Violation |
B |
Report |
1089650 |
03/16/2021 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.8 MPN/100 mL at EFF-001. |
Taking more precautions at the time of sampling. |
Violation |
B |
eSMR |
1092250 |
03/04/2021 |
DMON |
The Discharger indicated missing UV Dose data between 4 March 2021 and 10 March 2021 was due to a failure of the human machine interface (HMI) panel. The issue was resolved on 10 March 2021 by the Facility¿s SCADA contractor. |
The issue was resolved on 10 March 2021 by the Facility¿s SCADA contractor. |
Violation |
B |
Report |
1089649 |
03/03/2021 |
CAT1 |
Ammonia, Total (as N) Weekly Average limit is 1.7 mg/L and reported value was 01.84 mg/L at EFF-001. |
Decreased wasting rate slowly to increase MLSS |
Violation |
U |
eSMR |
1092249 |
02/28/2021 |
DMON |
The Discharger failed to conduct Emergency Storage Basin monitoring for wastewater diversions to the basins in February 2021. The Discharger indicated staff have been reminded regarding the monitoring requirements contained in the MRP when wastewater is diverted to the Emergency Storage Basins. |
The Discharger indicated staff have been reminded regarding the monitoring requirements contained in the MRP when wastewater is diverted to the Emergency Storage Basins. |
Violation |
B |
Report |
1084615 |
12/24/2020 |
DMON |
Sample was taken (effluent BOD) and the lab signed for, but did not place sample bottle in their cooler. They left it in the refrigerator. |
Staff now checks refrigerator after sample pick up |
Violation |
B |
eSMR |
1084614 |
12/24/2020 |
DMON |
Sample was taken (effluent TSS) and the lab signed for, but did not place sample bottle in their cooler. They left it in the refrigerator. |
Staff now checks refrigerator after sample pick up. |
Violation |
U |
eSMR |
1085819 |
12/21/2020 |
Order Conditions |
Daily average UV transmittance fell below the required amount of >/= 55% on 12/21/2020 and 12/22/2020 (recorded at 34% and 49% respecively) |
|
Violation |
B |
Report |
1084617 |
12/21/2020 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 3.3 MPN/100 mL at UVS-001. |
complete construction |
Violation |
B |
eSMR |
1084616 |
12/17/2020 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
complete construction. |
Violation |
B |
eSMR |
1081816 |
10/02/2020 |
Order Conditions |
The 1/4" tube that fed the UVT meter sprung a seep and the inside of the UVT meter got water in it causing the couvette to fog up. You could clean the couvette and the UVT would go back up to >70%, but that only lasted until the couvette fogged up again. |
The desiccant bag inside the meter was changed as soon as one could be found and UVT raised above 75% consistently. We now have a stock of ten desiccant bags incase this were to happen again. |
Violation |
B |
eSMR |
1080885 |
09/22/2020 |
OEV |
Total Coliform Not to exceed a specific limit more than once within any 30-day period. limit is 23 MPN/100 mL and reported value was 49 MPN/100 mL at UVS-001. |
UV channel past UV is now scrubbed and then any algae and debris netted before any sample. Once a month during cleaning, UV channel is disinfected. |
Violation |
B |
eSMR |
1080884 |
09/21/2020 |
OEV |
Total Coliform Not to exceed a specific limit more than once within any 30-day period. limit is 23 MPN/100 mL and reported value was 33 MPN/100 mL at UVS-001. |
UV channel past UV is now scrubbed and then any algae and debris netted before any sample. Once a month during cleaning, UV channel is disinfected. |
Violation |
B |
eSMR |
1080883 |
09/08/2020 |
OEV |
Total Coliform Daily Maximum limit is 240 MPN/100 mL and reported value was 540 MPN/100 mL at UVS-001. |
UV channel past UV is now scrubbed and then any algae and debris netted before any sample. Once a month during cleaning, UV channel is disinfected. |
Violation |
B |
eSMR |
1078787 |
07/13/2020 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
reset UV channel depth by adjusting slide gate buoyancy, scrubbed channel, disinfected channel and raised the MLVSS. |
Violation |
B |
eSMR |
1078792 |
07/10/2020 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
reset UV channel depth by adjusting slide gate buoyancy, scrubbed channel, disinfected channel and raised the MLVSS. |
Violation |
B |
eSMR |
1078791 |
07/09/2020 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
reset UV channel depth by adjusting slide gate buoyancy, scrubbed channel, disinfected channel and raised the MLVSS. |
Violation |
B |
eSMR |
1078790 |
07/08/2020 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
reset UV channel depth by adjusting slide gate buoyancy, scrubbed channel, disinfected channel and raised the MLVSS. |
Violation |
B |
eSMR |
1072942 |
02/24/2020 |
UAUTHDISC |
There was an unauthorized discharge of biosolids from the temporary centrifuge outside of the Biosolids Dewatering Room on 24 February 2020. The Facility¿s Sludge Centrifuge was out of service for repairs during the Board inspection of the Facility. A temporary centrifuge was being used by to dewater the biosolids. A malfunction occurred with the temporary centrifuge discharge pump causing a spill of approximately 1,500 gallons of biosolids on the paved and unpaved surfaces on the east side of the Facility. The weather was dry when the spill occurred and the biosolids did not reach surface water. Facility staff recovered some of the dried biosolids from spill by raking and shoveling the spill area. Recovered biosolids were placed in the sludge haul truck and the grit disposal container. |
|
Violation |
B |
Inspection |
1071904 |
02/10/2020 |
OEV |
Temperature Instantaneous Maximum limit is 20 Degrees F and reported value was 21 Degrees F at EFF-002. |
There is little that can be done to alter the effluent temperature currently. |
Violation |
B |
eSMR |
1071295 |
01/31/2020 |
Order Conditions |
There were two peak turbidities in excess of 10 ntu (one happened during a cleaning procedure where the meter was not placed on hold) and day of average turbidity > 2 ntu. |
Staff is continuing to work with decanter manufacturers and engineers and filter manufacturers in an attempt to lower turbidity. |
Violation |
B |
eSMR |
1071294 |
01/23/2020 |
OEV |
Temperature Instantaneous Maximum limit is 20 Degrees F and reported value was 21 Degrees F at EFF-002. |
There is no corrective action at this time |
Violation |
B |
eSMR |
1073490 |
12/31/2019 |
Order Conditions |
Exceeded Daily Average and Instantaneous Maximum turbidity limitations on multiple occasions in December 2019 |
|
Violation |
B |
Report |
1073491 |
12/31/2019 |
Order Conditions |
UV Transmittance fell below 55% on 12/16/2019 and 12/17/2019. |
|
Violation |
B |
Report |
1067435 |
10/31/2019 |
CAT1 |
Ammonia, Total (as N) Monthly Average limit is 0.8 mg/L and reported value was 1.989 mg/L at EFF-001. |
Staff has had a program installed that will call out and alert us when the SCADA clocks and the PLC clocks get out sync. This should prevent this type of issue. |
Violation |
B |
eSMR |
1071275 |
10/12/2019 |
Deficient Reporting |
The Discharger failed to monitor and report turbidity on two occasions in October 2019 as shown in Table B. The Discharger indicated there was a problem with the turbidimeter that prevented it from recording turbidity on the two days shown. |
The Discharger contacted the turbidimeter manufacturer and fixed the problem with new software downloaded from the turbidimeter manufacture's website. |
Violation |
B |
Report |
1067438 |
10/08/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
Staff has had a program installed that will call out and alert us when the SCADA clocks and the PLC clocks get out sync. This should prevent this type of issue. |
Violation |
B |
eSMR |
1067436 |
10/05/2019 |
CAT1 |
Ammonia, Total (as N) Weekly Average limit is 1.7 mg/L and reported value was 4.1 mg/L at EFF-001. |
Staff has had a program installed that will call out and alert us when the SCADA clocks and the PLC clocks get out sync. This should prevent this type of issue. |
Violation |
B |
eSMR |
1067437 |
10/02/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 3.3 MPN/100 mL at UVS-001. |
Staff has had a program installed that will call out and alert us when the SCADA clocks and the PLC clocks get out sync. This should prevent this type of issue. |
Violation |
B |
eSMR |
1065986 |
09/30/2019 |
Order Conditions |
there were some turbidities that exceeded 5.0 ntu. |
routine cleaning of the filter feed bay is controlling these violations. |
Violation |
U |
eSMR |
1065988 |
09/09/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 3.2 MPN/100 mL at UVS-001. |
We actually hired a second lab to do Total Coliform samples to see if there are changes and dissimilarities between the labs. |
Violation |
B |
eSMR |
1065987 |
09/04/2019 |
OEV |
Total Coliform Instantaneous Maximum limit is 240 MPN/100 mL and reported value was 1600 MPN/100 mL at UVS-001. |
all sampling equipment was washed and disinfected after we received the sample results. |
Violation |
B |
eSMR |
1065985 |
09/02/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 17 MPN/100 mL at UVS-001. |
UV channel was cleaned after last month. |
Violation |
B |
eSMR |
1064674 |
08/31/2019 |
Order Conditions |
There were numerous instances of high turbidity early in the month. |
The ponds were drained enough so we could clean the filter feed bay and flow the influent to the ponds for later treatment. This has allowed the turbidity to decrease. |
Violation |
B |
eSMR |
1064668 |
08/31/2019 |
CAT1 |
Ammonia, Total (as N) Monthly Average (Mean) limit is 0.8 ml/L and reported value was 3.2 ml/L at EFF-001. |
Blower shuttle valve was repaired, along with pressure relief valve, which allowed staff to run two blowers. It takes a little over a week for the plant to recover. Plant was compliant by August 15th. |
Violation |
B |
eSMR |
1064673 |
08/31/2019 |
CAT1 |
Ammonia, Total (as N) Monthly Average (Mean) limit is 20 lb/day and reported value was 26.8 lb/day at EFF-001. |
Blower shuttle valve was repaired, along with pressure relief valve, which allowed staff to run two blowers. It takes a little over a week for the plant to recover. Plant was compliant by August 15th. There was a possibility that with extra sampling we could have lowered the monthly average, but we knew we could not meet the numerical average. We did not think we would meet loading average, so did not take extra samples. |
Violation |
B |
eSMR |
1064672 |
08/30/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 17 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064683 |
08/29/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064663 |
08/28/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.8 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064662 |
08/27/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.8 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064661 |
08/26/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.8 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064677 |
08/23/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.8 MPN/100 mL at EFF-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064678 |
08/22/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.8 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064676 |
08/21/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.8 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064687 |
08/20/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.8 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064675 |
08/19/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 6.8 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064666 |
08/16/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 21 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064682 |
08/15/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 21 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1070632 |
08/14/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 21 MPN/100 mL at UVS-001. |
|
Violation |
B |
Report |
1064688 |
08/14/2019 |
OEV |
Total Coliform Not to exceed a specific limit more than once within any 30-day period. limit is 23 MPN/100 mL and reported value was 32 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1070631 |
08/13/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 14 MPN/100 mL at UVS-001. |
|
Violation |
B |
Report |
1064679 |
08/13/2019 |
OEV |
Total Coliform Not to exceed a specific limit more than once within any 30-day period. limit is 23 MPN/100 mL and reported value was 110 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064664 |
08/12/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 14 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064671 |
08/09/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 14 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064670 |
08/08/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 14 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064669 |
08/07/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 14 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064667 |
08/07/2019 |
CAT1 |
Ammonia, Total (as N) Weekly Average (Mean) limit is 1.7 mg/L and reported value was 8.3 mg/L at EFF-001. |
Blower shuttle valve was repaired, along with pressure relief valve, which allowed staff to run two blowers. It takes a little over a week for the plant to recover. Plant was compliant by August 15th. |
Violation |
B |
eSMR |
1070629 |
08/07/2019 |
CAT1 |
Ammonia, Total (as N) Weekly Average (Mean) limit is 43 lb/day and reported value was 72 lb/day at EFF-001. |
|
Violation |
B |
Report |
1064681 |
08/06/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 14 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064684 |
08/06/2019 |
OEV |
Total Coliform Not to exceed a specific limit more than once within any 30-day period. limit is 23 MPN/100 mL and reported value was 49 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064680 |
08/05/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 7.8 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064665 |
08/03/2019 |
CAT1 |
Ammonia, Total (as N) Weekly Average limit is 1.7 mg/L and reported value was 5.07 mg/L at EFF-001. |
Blower shuttle valve was repaired, along with pressure relief valve, which allowed staff to run two blowers. It takes a little over a week for the plant to recover. Plant was compliant by August 15th. |
Violation |
B |
eSMR |
1064686 |
08/02/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.5 MPN/100 mL. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1064685 |
08/01/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
First, UV channel was taken off line and every quartz sleeve cleaned. That did not provide us with low enough coliform readings. We then used a fire hose to clean the channel and remove any growth. That did not provide us with compliant coliform totals. We finally disinfected the channel with bleach near the end of the month and sent the chlorinated water and rinse water to the holding ponds for later treatment. Judging by September coliform numbers, this seems to have cured the problem, which was probably a regrowth of coliform organisms. |
Violation |
B |
eSMR |
1063097 |
07/31/2019 |
Order Conditions |
There were seven days where the average turbidity exceeded 2.0 ntu. |
While an improvement over previous months, staff is now embarking on a program to bypass the effluent to the ponds for future treatment and clean out the filter feed bay at least twice per month. |
Violation |
B |
eSMR |
1063096 |
07/31/2019 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
Staff is now cleaning the UV system and the filter feed basin every two weeks in an attempt to prevent higher numbers. |
Violation |
B |
eSMR |
1063095 |
07/30/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
Staff is now cleaning the UV system and the filter feed basin every two weeks in an attempt to prevent higher numbers. |
Violation |
B |
eSMR |
1079682 |
07/03/2019 |
Order Conditions |
there was a low UVT reading that existed for a couple of hours. A pump quit running and when it was restarted it discharged some sludge into the bay that feeds the UVT feed pump. |
Immediate flushing of the UVT would have been the proper call and that is the procedure when staff is on site now. |
Violation |
B |
eSMR |
1061683 |
06/30/2019 |
Order Conditions |
Effluent turbidity rose above the 10 NTU max and at time over the 5 NTU for 5% of the time limit. |
Filters were rebuilt by the end of the month and violations ceased. |
Violation |
U |
eSMR |
1061689 |
06/14/2019 |
OEV |
Total Coliform Not to exceed a specific limit more than once within any 30-day period. limit is 23 MPN/100 mL and reported value was 49 MPN/100 mL at UVS-001. |
We have replaced every bulb in the UV units, along with repairing all defective ballasts in order to provide the highest possible dosage to the effluent. |
Violation |
B |
eSMR |
1061684 |
06/11/2019 |
OEV |
Total Coliform 7-Day Median limit is 02.2 MPN/100 mL and reported value was 3.3 MPN/100 mL at UVS-001. |
We have replaced every bulb in the UV units, along with repairing all defective ballasts in order to provide the highest possible dosage to the effluent. |
Violation |
B |
eSMR |
1061682 |
06/10/2019 |
OEV |
Total Coliform 7-Day Median limit is 2.2 MPN/100 mL and reported value was 4.5 MPN/100 mL at UVS-001. |
We have replaced every bulb in the UV units, along with repairing all defective ballasts in order to provide the highest possible dosage to the effluent. |
Violation |
B |
eSMR |
Report displays most recent five years of violations. Refer to the Interactive Violation Report for more data.
|