| Violation ID |
Occurred Date |
Violation Type |
(-) Violation Description |
Corrective Action |
Status |
Classification |
Source |
| 1118266 |
05/28/2023 |
Deficient Reporting |
The eSMR is missing a required result at location INF-001 for Conductivity for the week of May 28, 2023. A mix up within the City laboratory led to the sample being discarded before being analyzed. |
Laboratory staff have been reminded of internal process and policies to track samples as they move through the laboratory. |
Violation |
U |
eSMR |
| 1105753 |
05/29/2022 |
DMON |
The eSMR is missing a required result for BOD at location INF-001 for May 29, 2022. The Laboratory missed the readback time for BOD and the results for the batch were deemed unreportable. |
Laboratory staff have been reminded of their responsibilities to check timelines for set and readback runtimes and adhere to the method requirements. The city does not foresee this being a reoccurring issue. |
Violation |
U |
eSMR |
| 1103643 |
03/22/2022 |
Order Conditions |
Based on the influent calibration records, the annual calibration of the influent Parshall flumes was overdue, as it is required on 20 January 2022. According to MRP Provision I.D of the WDRs, “Appropriate flow measurement devices and methods consistent with accepted scientific practices shall be selected and used to ensure the accuracy and reliability of measurements of the volume of monitored discharges. All monitoring instruments and devices used by the Discharger to fulfill the prescribed monitoring program shall be properly maintained and calibrated as necessary, at least yearly, to ensure their continued accuracy. All flow measurement devices shall be calibrated at least once per year to ensure continued accuracy of the devices.” |
|
Violation |
B |
Inspection |
| 1103642 |
03/22/2022 |
Order Conditions |
During the inspection, it was discovered that one of the UV module’s bulbs exceeded the manufacture’s recommended hours, 12,000 run hours, by 471 hours. According to the Standard Provision I.D, “The Discharger shall, at all times, properly operate and maintain all facilities and systems of treatment and control (and related appurtenances) which are installed or used by the Discharger to achieve compliance with the conditions of this Order.” According to the Discharger, it was due to an oversight and the Discharger will replace the bulbs and update the Standard Operating Procedures (SOPs) to ensure the bulbs not exceeding the recommended hours in the future. |
|
Violation |
B |
Inspection |
| 1103438 |
03/18/2022 |
Order Conditions |
The eSMR does not include required results for BOD at location INF-001 for March 18, 20, and 21, 2022 due to QC failures. |
The City laboratory is researching alternative seed locations to ensure a more reliable quality control result. |
Violation |
U |
eSMR |
| 1102709 |
02/03/2022 |
Order Conditions |
The eSMR does not include required results for BOD at location INF-001 for February 3, 2022 due to an instrumentation programming failure, as well as a procedural breakdown during initial set up in the City laboratory. |
Set up procedure has been reviewed with laboratory staff to avoid future occurrences of this issue. |
Violation |
B |
eSMR |
| 1099778 |
12/21/2021 |
DMON |
The eSMR does not include required results for BOD at location INF-001 for December 21 ¿ 23, 2021. |
The City laboratory experienced a QC failure due to a seed strength issue. The City believes that the unusually low concentration from the seed location may be attributed to the exceptional amount of rain experienced in December 2021. |
Violation |
B |
eSMR |
|
Report displays most recent five years of violations. Refer to the Interactive Violation Report for more data.
|