| Violation ID |
Occurred Date |
Violation Type |
(-) Violation Description |
Corrective Action |
Status |
Classification |
Source |
| 1159888 |
09/30/2026 |
DMON |
Influent flow metering data is unavailable in Sept. 2026 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The influent flow meter will be operational with the new WWTF in 2028.
|
Violation |
U |
eSMR |
| 1159402 |
09/15/2026 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1159695 |
08/31/2026 |
DMON |
Influent flow metering data is unavailable in August 2026 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The influent flow meter will be operational with the new WWTF in 2028.
|
Violation |
U |
eSMR |
| 1159225 |
08/01/2026 |
LREP |
Once Only OneTime ( TECHRPT ) (Analytical Methods Report (MRP X.D.1)) report for 2026/07/01 (3158008) was due on 31-JUL-26 |
|
Violation |
B |
Report |
| 1158960 |
07/31/2026 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1156668 |
06/30/2026 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1156667 |
06/30/2026 |
DMON |
Influent flow metering data was unavailable July- December 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1156058 |
05/31/2026 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
|
The SCADA reporting failure is being investigated.
|
Violation |
U |
eSMR |
| 1156059 |
05/31/2026 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1156060 |
05/31/2026 |
CAT2 |
Copper, Total Recoverable Monthly Average limit is 2 ug/L and reported value was 5.2 ug/L at EFF-001. |
Alternative measures to achieve temporary compliance are being investigated. Construction of the new EPWWTF is in progress and is scheduled to be completed in 2028.
|
Violation |
U |
eSMR |
| 1154711 |
04/30/2026 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
|
The SCADA reporting failure is being investigated.
|
Violation |
U |
eSMR |
| 1154712 |
04/30/2026 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1154710 |
04/30/2026 |
DMON |
The discharge flow meter calibration was not completed for the calendar year 2025. |
An appointment has been made to calibrate the discharge flow meter. |
Violation |
U |
eSMR |
| 1153577 |
03/31/2026 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
|
The SCADA reporting failure is being investigated.
|
Violation |
U |
eSMR |
| 1153580 |
03/31/2026 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
|
The SCADA reporting failure is being investigated.
|
Violation |
U |
eSMR |
| 1153576 |
03/31/2026 |
DMON |
Influent flow metering data is unavailable in March 2026 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing calendar year annual average of Effluent EC. |
The manufacturer has been contacted to repair the metering equipment. The SCADA reporting failure is being investigated.
|
Violation |
B |
eSMR |
| 1153579 |
03/31/2026 |
DMON |
Influent flow metering data is unavailable in March 2026 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1153578 |
03/31/2026 |
Order Conditions |
The discharge flow meter calibration was not completed for the calendar year 2025. |
An appointment has been made to calibrate the discharge flow meter. |
Violation |
B |
eSMR |
| 1152639 |
03/02/2026 |
LREP |
Monthly SMR ( MONNPDES ) (Monthly SMR) report for January 2026 (3094071) was due on 01-MAR-26 |
|
Violation |
B |
Report |
| 1152931 |
02/28/2026 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1152930 |
02/28/2026 |
Deficient Reporting |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
|
The SCADA reporting failure is being investigated.
|
Violation |
U |
eSMR |
| 1151663 |
02/02/2026 |
LREP |
Annual SMR ( TECHRPT ) (Annual Operations Report) report for 2025 (3094069) was due on 01-FEB-26 |
|
Violation |
B |
Report |
| 1152227 |
02/02/2026 |
LREP |
Annual SMR ( TECHRPT ) (Annual Operations Report) report for 2025 (3098212) was due on 01-FEB-26 |
|
Violation |
B |
Report |
| 1151274 |
02/02/2026 |
LREP |
Monthly SMR ( MONNPDES ) (Monthly SMR) report for December 2025 (3032538) was due on 01-FEB-26 |
|
Violation |
B |
Report |
| 1152709 |
01/31/2026 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing RSW-001 & RSW-002 Observations for the month. |
The manufacturer has been contacted to repair the metering equipment. The SCADA reporting failure is being investigated.
|
Violation |
B |
eSMR |
| 1152710 |
01/31/2026 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1151252 |
01/31/2026 |
LREP |
Annual SMR ( MONNPDES ) (Chronic WET Test) report for 2025 (2269172) was due on 30-JAN-26 |
|
Violation |
B |
Report |
| 1151250 |
01/31/2026 |
LREP |
Annual SMR ( MONNPDES ) (Chronic WET Test) report for 2025 (3027487) was due on 30-JAN-26 |
|
Violation |
B |
Report |
| 1151251 |
01/31/2026 |
LREP |
Quarterly SMR ( MONNPDES ) (Acute WET Test) report for Q4 2025 (3027486) was due on 30-JAN-26 |
|
Violation |
B |
Report |
| 1160811 |
01/09/2026 |
CAT2 |
Copper, Total Monthly Average limit is 2.0 ug/L and reported value was 2.7 ug/L at EFF-001. |
|
Violation |
B |
Report |
| 1153563 |
12/31/2025 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning. |
The SCADA reporting failure is being investigated. |
Violation |
U |
eSMR |
| 1151606 |
12/31/2025 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
|
The SCADA reporting failure is being investigated.
|
Violation |
U |
eSMR |
| 1152932 |
12/31/2025 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
|
The SCADA reporting failure is being investigated.
|
Violation |
U |
eSMR |
| 1153564 |
12/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1151608 |
12/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing Acute Toxicity Report. |
The manufacturer has been contacted to repair the metering equipment. The SCADA reporting failure is being investigated.
|
Violation |
B |
eSMR |
| 1151610 |
12/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing EFF-001 Phosphorus (1/qtr); RSW-001 & RSW-002 Observations for the month; RSW-001 turbidity (1/qtr) and RSW-002 turbidity (1/qtr); and missing Effluent Standard Minerals (1/yr). |
The manufacturer has been contacted to repair the metering equipment. The SCADA reporting failure is being investigated.
|
Violation |
B |
eSMR |
| 1151607 |
12/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1151609 |
12/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1151611 |
12/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1152933 |
12/31/2025 |
DMON |
Influent flow metering data was unavailable July- December 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1160810 |
12/31/2025 |
OEV |
Electrical Conductivity @ 25 Deg. C Annual Average (Mean) limit is 925 umhos/cm and reported value was 952.245 umhos/cm at EFF-001. |
|
Violation |
B |
Report |
| 1160790 |
12/19/2025 |
CAT2 |
Copper, Total Daily Maximum limit is 4.0 ug/L and reported value was 4.2 ug/L at EFF-001. |
|
Violation |
B |
Report |
| 1160789 |
12/19/2025 |
CAT2 |
Copper, Total Monthly Average limit is 2.0 ug/L and reported value was 4.2 ug/L at EFF-001. |
|
Violation |
B |
Report |
| 1149951 |
12/02/2025 |
LREP |
Monthly SMR ( MONNPDES ) (Monthly SMR) report for October 2025 (3027490) was due on 01-DEC-25 |
|
Violation |
B |
Report |
| 1150034 |
11/30/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing EFF-001 Copper (1x) and Zinc (1x); RSW-001 & RSW-002 Observations for the month. |
The manufacturer has been contacted to repair the metering equipment.
The SCADA reporting failure is being investigated.
|
Violation |
B |
eSMR |
| 1150035 |
11/30/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1149406 |
11/02/2025 |
LREP |
Monthly SMR ( MONNPDES ) (Monthly SMR) report for September 2025 (3027489) was due on 01-NOV-25 |
|
Violation |
B |
Report |
| 1149955 |
10/31/2025 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
|
The SCADA reporting failure is being investigated.
|
Violation |
U |
eSMR |
| 1149954 |
10/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing RSW-001 & RSW-002 Observations for the month. |
The manufacturer has been contacted to repair the metering equipment. The SCADA reporting failure is being investigated.
|
Violation |
B |
eSMR |
| 1149354 |
10/31/2025 |
LREP |
Quarterly SMR ( MONNPDES ) (Acute WET Test) report for Q3 2025 (2269170) was due on 30-OCT-25 |
|
Violation |
B |
Report |
| 1149352 |
10/31/2025 |
LREP |
Quarterly SMR ( MONNPDES ) (Acute WET Test) report for Q3 2025 (3027485) was due on 30-OCT-25 |
|
Violation |
B |
Report |
| 1160788 |
10/23/2025 |
CAT2 |
Copper, Total Daily Maximum limit is 4.0 ug/L and reported value was 4.2 ug/L at EFF-001. |
|
Violation |
B |
Report |
| 1160787 |
10/23/2025 |
CAT2 |
Copper, Total Monthly Average limit is 2.0 ug/L and reported value was 4.2 ug/L at EFF-001. |
|
Violation |
B |
Report |
| 1153575 |
09/30/2025 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning. |
The SCADA reporting failure is being investigated. |
Violation |
U |
eSMR |
| 1153574 |
09/30/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1150036 |
09/30/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing Toxicity Report. |
The manufacturer has been contacted to repair the metering equipment.
The SCADA reporting failure is being investigated.
|
Violation |
B |
eSMR |
| 1149953 |
09/30/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1150037 |
09/30/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1149952 |
09/30/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing EFF-001 Copper (1/month) and Zinc (1/month); RSW-001 & RSW-002 Observations for the month and turbidity (1/qtr); Pond-001 DO (1x) and pH (1x); and Pond-002 DO (2x) and pH (2x). |
The manufacturer has been contacted to repair the metering equipment.
The SCADA reporting failure is being investigated.
|
Violation |
B |
eSMR |
| 1147210 |
09/02/2025 |
LREP |
Monthly SMR ( MONNPDES ) (Monthly SMR) report for July 2025 (2269179) was due on 01-SEP-25 |
|
Violation |
B |
Report |
| 1147225 |
08/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1147224 |
08/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing RSW-001 & RSW-002 Observations for the month. |
The manufacturer has been contacted to repair the metering equipment. The SCADA reporting failure is being investigated.
|
Violation |
B |
eSMR |
| 1160786 |
08/21/2025 |
CAT2 |
Copper, Total Daily Maximum limit is 4.0 ug/L and reported value was 5.2 ug/L at EFF-001. |
|
Violation |
B |
Report |
| 1160785 |
08/21/2025 |
CAT2 |
Copper, Total Monthly Average limit is 2.0 ug/L and reported value was 5.2 ug/L at EFF-001. |
|
Violation |
B |
Report |
| 1146056 |
08/02/2025 |
LREP |
Monthly SMR ( MONNPDES ) (Monthly SMR) report for June 2025 (2269178) was due on 01-AUG-25 |
|
Violation |
B |
Report |
| 1147223 |
07/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1147222 |
07/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing EFF-001 Dissolved Organic Carbon (1/qtr); percent removal for BOD and TSS; missing RSW-001 & RSW-002 Dissolved Organic Carbon (1/qtr); and RSW-001 & RSW-002 Observations for the month. |
The manufacturer has been contacted to repair the metering equipment. The SCADA reporting failure is being investigated. |
Violation |
B |
eSMR |
| 1145970 |
07/31/2025 |
LREP |
Quarterly SMR ( MONNPDES ) (Acute WET Test) report for Q2 2025 (2269169) was due on 30-JUL-25 |
|
Violation |
B |
Report |
| 1144840 |
07/02/2025 |
LREP |
Monthly SMR ( MONNPDES ) (Monthly SMR) report for May 2025 (2269177) was due on 01-JUL-25 |
|
Violation |
B |
Report |
| 1148300 |
06/30/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing RSW-001 & RSW-002 observations for the month. |
The manufacturer has been contacted to repair the metering equipment. The SCADA reporting failure is being investigated.
|
Violation |
B |
eSMR |
| 1148301 |
06/30/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1144008 |
06/02/2025 |
LREP |
Monthly SMR ( MONNPDES ) (Monthly SMR) report for April 2025 (2269176) was due on 01-JUN-25 |
|
Violation |
B |
Report |
| 1148296 |
05/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing RSW-001 & RSW-002 observations for the month. |
The SCADA reporting failure is being investigated.
|
Violation |
B |
eSMR |
| 1148297 |
05/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
U |
eSMR |
| 1143346 |
05/02/2025 |
LREP |
Monthly SMR ( MONNPDES ) (Monthly SMR) report for March 2025 (2269175) was due on 01-MAY-25 |
|
Violation |
B |
Report |
| 1143306 |
05/01/2025 |
LREP |
Quarterly SMR ( MONNPDES ) (Acute WET Test) report for Q1 2025 (2269168) was due on 30-APR-25 |
|
Violation |
B |
Report |
| 1148295 |
04/30/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing RSW-001 & RSW-002 Observations for the month; missing RSW turbidity (1/qtr). |
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
B |
eSMR |
| 1148294 |
04/30/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing RSW-001 & RSW-002 Observations for the month; missing RSW turbidity (1/qtr).
|
The SCADA reporting failure is being investigated.
|
Violation |
B |
eSMR |
| 1142142 |
04/02/2025 |
LREP |
Monthly SMR ( MONNPDES ) (Monthly SMR) report for February 2025 (2269174) was due on 01-APR-25 |
|
Violation |
B |
Report |
| 1148299 |
03/31/2025 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
|
The SCADA reporting failure is being investigated.
|
Violation |
U |
eSMR |
| 1148298 |
03/31/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
B |
eSMR |
| 1153581 |
03/31/2025 |
DMON |
The discharge flow meter calibration was not completed for the calendar year 2025. |
An appointment has been made to calibrate the discharge flow meter. |
Violation |
U |
eSMR |
| 1148292 |
02/28/2025 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
|
The SCADA reporting failure is being investigated.
|
Violation |
U |
eSMR |
| 1148293 |
02/28/2025 |
DMON |
Influent flow metering data is unavailable in July 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning.
Missing effluent Phosphorous (1/qtr); missing Pond Copper (1/qtr); and missing RSW Observations for the month.
|
The manufacturer has been contacted to repair the metering equipment.
|
Violation |
B |
eSMR |
| 1140067 |
02/02/2025 |
LREP |
Annual SMR ( TECHRPT ) (Annual Operations Report) report for 2024 (2269167) was due on 01-FEB-25 |
|
Violation |
B |
Report |
| 1140609 |
01/31/2025 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning. |
The SCADA reporting failure is being investigated. |
Violation |
U |
eSMR |
| 1140608 |
01/31/2025 |
DMON |
Influent flow metering data is unavailable in January 2025 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
B |
eSMR |
| 1160768 |
12/31/2024 |
DMON |
2024 Annual Report missing calendar year annual average of Effluent EC. |
|
Violation |
B |
Report |
| 1138924 |
12/31/2024 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning. |
The SCADA reporting failure is being investigated. |
Violation |
U |
eSMR |
| 1138923 |
12/31/2024 |
DMON |
Influent flow metering data is unavailable in December 2024 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations.
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
B |
eSMR |
| 1137757 |
11/30/2024 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning. |
The SCADA failure is being investigated. |
Violation |
U |
eSMR |
| 1136043 |
10/31/2024 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning. |
The SCADA failure is being investigated. |
Violation |
U |
eSMR |
| 1134584 |
09/01/2024 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning,. |
The SCADA failure is being investigated. |
Violation |
U |
eSMR |
| 1131769 |
08/01/2024 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning. |
The SCADA failure is being investigated. |
Violation |
U |
eSMR |
| 1131768 |
08/01/2024 |
DMON |
Influent flow metering data is unavailable before August 24, 2024 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The meter has been repaired and calibration occurred August 27, 2024. |
Violation |
U |
eSMR |
| 1130919 |
07/01/2024 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month. Daily grab data from the UV disinfection equipment indicates the equipment is functioning. |
The SCADA failure is being investigated. |
Violation |
U |
eSMR |
| 1130918 |
07/01/2024 |
DMON |
Influent flow metering data is unavailable in July 2024 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly
suspended solids loading calculations. |
The meter has been repaired and calibration should occur August 27, 2024. |
Violation |
U |
eSMR |
| 1129559 |
06/06/2024 |
OEV |
pH Daily Minimum limit is 6.5 SU and reported value was 6.3 SU at EFF-001. |
The chemical feed pump has been replaced. |
Violation |
U |
eSMR |
| 1134636 |
06/02/2024 |
LREP |
Late April eSMR 2024 submittal. It was due on 06/01/2024 and submitted on 06/04/2024 (3 days late). |
|
Violation |
B |
Report |
| 1129557 |
06/01/2024 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum, daily average, and weekly average dosing data in the month of June. |
Daily grab data from the UV disinfection equipment indicates the equipment is functioning, however the SCADA failure is being investigated. |
Violation |
U |
eSMR |
| 1129558 |
06/01/2024 |
DMON |
Influent flow metering data is unavailable in June 2024 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The meter has been repaired and installation should occur soon. |
Violation |
U |
eSMR |
| 1128658 |
05/31/2024 |
DMON |
Influent flow metering data is unavailable in May 2024 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1128657 |
05/09/2024 |
DMON |
A SCADA system error resulted in the failure to collect some of the daily UV minimum and average dosing data in the month. |
The SCADA failure is being investigated. |
Violation |
U |
eSMR |
| 1128374 |
04/26/2024 |
DMON |
From April 26-30 there was a failure in the continuous turbidity monitoring equipment.
|
This error has been corrected. |
Violation |
U |
eSMR |
| 1128376 |
04/01/2024 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum dosing data in the month. |
The SCADA failure is currently being investigated. |
Violation |
U |
eSMR |
| 1128375 |
04/01/2024 |
DMON |
Influent flow metering data is unavailable in April 2024 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1125993 |
03/01/2024 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum dosing data in the month. |
The SCADA failure is currently being investigated. |
Violation |
U |
eSMR |
| 1125994 |
03/01/2024 |
DMON |
Influent flow metering data is unavailable in March 2024 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1125120 |
02/29/2024 |
DMON |
A SCADA system error resulted in the failure to collect all the daily UV minimum dosing data in the month. |
The SCADA failure is currently being investigated. |
Violation |
U |
eSMR |
| 1125121 |
02/29/2024 |
DMON |
Influent flow metering data is unavailable in February 2024 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1134635 |
02/02/2024 |
Deficient Reporting |
2023 Annual Operations Report - Missing calculation of the calendar annual average nitrite plus nitrate (as N) concentration in the effluent, as monitored at EFF-001 (X.D.1.f). |
|
Violation |
B |
Report |
| 1134634 |
02/02/2024 |
LREP |
2023 Annual Operations Report was due on 02/01/2024. The report was submitted on 02/14/2024 (13 days late). |
|
Violation |
B |
Report |
| 1124172 |
01/01/2024 |
DMON |
Influent flow metering data is unavailable in January 2024 due to automated metering equipment failure. The manufacturer has been contacted to repair the metering equipment. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1123295 |
12/01/2023 |
DMON |
Influent flow metering data is unavailable in December due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1122505 |
11/02/2023 |
DMON |
Influent flow metering data is unavailable from November 2, 2023 to November 30, 2023 due to automated metering equipment failure. The manufacturer has been contacted to repair the metering equipment. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations in November. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1119964 |
08/08/2023 |
OEV |
pH Daily Minimum limit is 6.5 SU and reported value was 5.7 SU at EFF-001. |
The pump was repaired, and the pH was returned to normal levels. |
Violation |
U |
eSMR |
| 1117773 |
05/05/2023 |
DMON |
Influent flow metering data is unavailable from May 5, 2023 to May 8, 2023 due to automated metering equipment failure. |
The equipment has been repaired. |
Violation |
U |
eSMR |
| 1116799 |
04/01/2023 |
DMON |
Influent flow metering data is unavailable from April 1, 2023 to April 8, 2023 due to automated metering equipment failure. The manufacturer has been contacted to repair the metering equipment. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations in April. |
Repaired. |
Violation |
U |
eSMR |
| 1115492 |
03/02/2023 |
DMON |
Influent flow metering data is unavailable from March 2, 2023 to March 31, 2023 due to automated metering equipment failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demand loading and weekly suspended solids loading calculations in March. |
The manufacturer has been contacted to repair the metering equipment. |
Violation |
U |
eSMR |
| 1113404 |
02/02/2023 |
LREP |
Annual SMR ( TECHRPT ) (Annual Operations Report) report for 2022 (2269131) was due on 01-FEB-23 |
|
Violation |
B |
Report |
| 1112506 |
12/01/2022 |
DMON |
Influent flow metering data is unavailable from December 1, 2022 to December 29, 2022 due to automated metering system failure. The manufacturer was able to repair the metering equipment and it has been returned to service. Influent calculations based on flow were unable to be calculated during this period. This includes weekly influent biochemical oxygen demands, loading and weekly suspended solids loading calculations in December. |
The manufacturer was able to repair the metering equipment and it has been returned to service. |
Violation |
U |
eSMR |
| 1111346 |
11/01/2022 |
DMON |
The El Portal influent flow meter for the month of November is inaccurate and requires repair. |
A request for repair has been initiated. |
Violation |
U |
eSMR |
| 1110526 |
10/27/2022 |
OEV |
pH Daily Minimum limit is 6.5 SU and reported value was 6.0 SU at EFF-001. |
A low influent pH of unknown origin was the cause and required an
increase of chemical feed to rectify. |
Violation |
U |
eSMR |
| 1107092 |
07/08/2022 |
OEV |
pH Daily Minimum limit is 6.5 SU and reported value was 6.2 SU at EFF-001. |
Lime equipment feed equipment repaired. |
Violation |
U |
eSMR |
| 1106272 |
06/16/2022 |
OEV |
pH Daily Minimum limit is 6.5 SU and reported value was 6.1 SU at EFF-001. |
|
Violation |
U |
eSMR |
| 1106271 |
06/15/2022 |
OEV |
pH Daily Minimum limit is 6.5 SU and reported value was 6.2 SU at EFF-001. |
|
Violation |
U |
eSMR |
| 1105433 |
05/10/2022 |
OEV |
pH Daily Minimum limit is 6.5 SU and reported value was 5.8 SU at EFF-001. |
Removed plug in chemical feed pump, reestablished chemical feed and correct the low pH. |
Violation |
U |
eSMR |
| 1103083 |
03/01/2022 |
DMON |
Influent flow metering data is unavailable in March due to automated metering system failure. Influent calculations based on flow were unable to be calculated during this period. This includes weekly biochemical oxygen demands, loading and weekly suspended solids loading calculations. |
Influent flow metering data was unavailable from December 18, 2021 to Mach 25, 2022 due to automated metering system failure. The manufacturer was able to repair the metering equipment and it has been returned to service. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demands, loading and weekly suspended solids loading calculations in March. |
Violation |
U |
eSMR |
| 1102263 |
02/01/2022 |
DMON |
Influent flow metering data is unavailable starting December 18, 2021 due to automated metering system failure. A third-party service technician was unable to repair the metering equipment and it has since been sent back to the manufacturer for service. There is no current estimate for repair. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demands, loading and weekly suspended solids loading calculations in February. |
Influent flow metering data is unavailable starting December 18, 2021 due to automated metering system failure. A third-party service technician was unable to repair the metering equipment and it has since been sent back to the manufacturer for service. There is no current estimate for repair. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demands, loading and weekly suspended solids loading calculations in February. |
Violation |
U |
eSMR |
| 1100901 |
01/01/2022 |
DMON |
INFLUENT FLOW METERING:
Influent flow metering data is unavailable starting December 18, 2021 due to automated metering system failure. A third-party service technician was unable to repair the metering equipment and it has since been sent back to the manufacturer for service. There is no current estimate for repair. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demands loading and weekly suspended solids loading calculations in January. |
The metering equipment and it has since been sent back to the manufacturer for service. |
Violation |
U |
eSMR |
| 1100902 |
01/01/2022 |
Deficient Reporting |
WEEKLY BIOCHEMICAL OXYGEN DEMAND LOADING VALUES:
Influent flow metering data is unavailable starting December 18, 2021 due to automated metering system failure. A third-party service technician was unable to repair the metering equipment and it has since been sent back to the manufacturer for service. There is no current estimate for repair. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demands loading and weekly suspended solids loading calculations in January. |
The metering equipment and it has since been sent back to the manufacturer for service. |
Violation |
U |
eSMR |
| 1100900 |
01/01/2022 |
Deficient Reporting |
WEEKLY SUSPENDED SOLIDS LOADING CALCULATIONS:
Influent flow metering data is unavailable starting December 18, 2021 due to automated metering system failure. A third-party service technician was unable to repair the metering equipment and it has since been sent back to the manufacturer for service. There is no current estimate for repair. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demands loading and weekly suspended solids loading calculations in January. |
The metering equipment and it has since been sent back to the manufacturer for service. |
Violation |
U |
eSMR |
| 1134637 |
12/31/2021 |
Deficient Reporting |
4th Quarter (October to December) 2021 - Missing RSW-001 and RSW-002 results for Dissolved Organic Carbon (1/quarter). |
|
Violation |
B |
Report |
| 1099205 |
12/22/2021 |
DMON |
Influent flow metering data is unavailable December 18, 2021 due to automated metering system failure. Influent calculations based on flow are unable to be calculated during this period. This includes weekly biochemical oxygen demands and weekly suspended solids calculation in December. |
A third-party service technician was unable to repair the metering equipment and it has since been sent back to the manufacturer for service. There is no current estimate for repair. |
Violation |
U |
eSMR |
| 1099206 |
12/18/2021 |
DMON |
Influent flow metering data is unavailable December 18-31, 2021 due to automated metering system failure. |
A third-party service technician was unable to repair the metering equipment and it has since been sent back to the manufacturer for service. There is no current estimate for repair. |
Violation |
U |
eSMR |
| 1099204 |
12/18/2021 |
OEV |
pH Daily Minimum limit is 6.5 SU and reported value was 6.1 SU at EFF-001. |
Repaired lime pump. |
Violation |
U |
eSMR |
|