Violation ID |
Occurred Date |
Violation Type |
(-) Violation Description |
Corrective Action |
Status |
Classification |
Source |
1130320 |
05/31/2024 |
OEV |
Total Coliform 30-Day Median limit is 70 MPN/100 mL and reported value was 81 MPN/100 mL at EFF-001. |
Increase Chlorine dose |
Violation |
U |
eSMR |
1130319 |
04/15/2024 |
OEV |
Enterococci 6-Week Rolling Geometric Mean limit is 30 MPN/100 mL and reported value was 33 MPN/100 mL at EFF-001. |
More MBR allocation |
Violation |
U |
eSMR |
1130317 |
04/08/2024 |
OEV |
Enterococci 6-Week Rolling Geometric Mean limit is 30 MPN/100 mL and reported value was 60 MPN/100 mL at EFF-001. |
More MBR allocation |
Violation |
U |
eSMR |
1130316 |
04/04/2024 |
OEV |
Enterococci 6-Week Rolling Geometric Mean limit is 30 MPN/100 mL and reported value was 71 MPN/100 mL at EFF-001. |
More MBR allocation |
Violation |
U |
eSMR |
1130318 |
04/01/2024 |
OEV |
Enterococci 6-Week Rolling Geometric Mean limit is 30 MPN/100 mL and reported value was 79 MPN/100 mL at EFF-001. |
More MBR allocation |
Violation |
U |
eSMR |
1126823 |
03/27/2024 |
OEV |
Enterococci 6-Week Rolling Geometric Mean limit is 30 CFU/100 mL and reported value was 98 CFU/100 mL at EFF-001. |
Increase MBR allocation and Chlorine Dose |
Violation |
B |
eSMR |
1126822 |
03/27/2024 |
OEV |
Enterococci Instantaneous Maximum limit is 110 CFU/100 mL and reported value was 292 CFU/100 mL at EFF-001. |
Increase MBR allocation and Chlorine Dose |
Violation |
B |
eSMR |
1126815 |
03/25/2024 |
OEV |
Enterococci 6-Week Rolling Geometric Mean limit is 30 CFU/100 mL and reported value was 81 CFU/100 mL at EFF-001. |
Increase MBR allocation and Chlorine Dose |
Violation |
B |
eSMR |
1126814 |
03/18/2024 |
OEV |
Enterococci 6-Week Rolling Geometric Mean limit is 30 CFU/100 mL and reported value was 72 CFU/100 mL at EFF-001. |
Increase MBR allocation and Chlorine Dose |
Violation |
B |
eSMR |
1126813 |
03/11/2024 |
OEV |
Enterococci 6-Week Rolling Geometric Mean limit is 30 CFU/100 mL and reported value was 115 CFU/100 mL at EFF-001. |
Increase MBR allocation and Chlorine Dose |
Violation |
B |
eSMR |
1126812 |
03/11/2024 |
OEV |
Total Coliform Other limit is 10 % and reported value was 14 % at RSW-001. *** MMP Exempt Reason:Receiving Water Sample |
Unable to control storm. |
Violation |
B |
eSMR |
1126820 |
03/04/2024 |
OEV |
Enterococci Instantaneous Maximum limit is 110 CFU/100 mL and reported value was 1200 CFU/100 mL at EFF-001. |
Increase MBR allocation and Chlorine Dose |
Violation |
B |
eSMR |
1126817 |
02/29/2024 |
OEV |
Total Coliform Monthly Median limit is 70 MPN/100 mL and reported value was 110 MPN/100 mL at EFF-001. |
Increase MBR allocation and Chlorine Dose |
Violation |
B |
eSMR |
1126821 |
02/26/2024 |
OEV |
Total Coliform Monthly Median limit is 70 MPN/100 mL and reported value was 79.5 MPN/100 mL at RSW-001. *** MMP Exempt Reason:Receiving Water Sample |
Unable to control storm. |
Violation |
B |
eSMR |
1126816 |
02/05/2024 |
OEV |
Enterococci Instantaneous Maximum limit is 110 CFU/100 mL and reported value was 549 CFU/100 mL at EFF-001. |
Increase MBR allocation and Chlorine Dose |
Violation |
B |
eSMR |
1126819 |
01/01/2024 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 mg/L and reported value was 1808 mg/L at EFF-001. |
Loss of SBS believed to be caused by malfunction in chemical pumps due to crystallization of SBS, and low volume in the tank.
Heat lamps were applied to increase the temperature of surrounding pipes, and the recirculating outside air was turned off. |
Violation |
B |
eSMR |
1123533 |
12/25/2023 |
OEV |
Enterococci Single Sample Maximum limit is 104 MPN/100 mL and reported value was 1180 MPN/100 mL at RSW-001. *** MMP Exempt Reason:Effluent monitoring for bacteria on 12/25/23 suggests that the elevated enterococci result is not related to the Facility's discharge. |
resampled 12/27/23 with a result of 31 MPN per 100 mL. |
Violation |
B |
eSMR |
1121319 |
09/25/2023 |
Surface Water |
Enterococci Instantaneous Maximum limit is 104 MPN/100 mL and reported value was 1184 MPN/100 mL at RSW-001. |
Out of our control |
Violation |
B |
eSMR |
1121320 |
09/25/2023 |
Surface Water |
Fecal Coliform Instantaneous Maximum limit is 400.0 MPN/100 mL and reported value was 2400.0 MPN/100 mL at RSW-001. *** MMP Exempt Reason:This is a Receiving Water Sample Result |
Out of our control. |
Violation |
B |
eSMR |
1118916 |
06/12/2023 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 ug/L and reported value was 3948 ug/L at EFF-001. |
Design and planning installation of a automatic transfer to City water, when C-water is lost. |
Violation |
A |
eSMR |
1118915 |
05/01/2023 |
OEV |
Fecal Coliform Instantaneous Maximum limit is 400 MPN/100 mL and reported value was 540 MPN/100 mL at EFF-001. |
Cleaned secondaries, and 3rd RBC Train. During the cleaning we will increase the chlorine dose to make up for the increased demand. |
Violation |
B |
eSMR |
1116210 |
03/31/2023 |
CAT1 |
BOD5 @ 20 Deg. C, Percent Removal Percent Reduction limit is 85 % and reported value was 84.33 % at EFF-001. |
During low Influent concentration, we could run more primary effluent though the MBR and less though the RBCs to increase the reduction |
Violation |
B |
eSMR |
1112887 |
12/26/2022 |
Order Conditions |
Enterococci Single Sample Maximum limit is 104 MPN/100 mL and reported value was 885 MPN/100 mL at RSW-001. *** MMP Exempt Reason:Receiving water sample - discharger not the cause of exceedance. |
We went into accelerated monitoring and sampled on 12/28/22 and it was 156 MPN/ 100ml. It was sampled again on 12/29/22 and the result was 20 MPN/ 100ml. Effluent grab enterococcus sampled on 12/26/22 was 770 MPN/ 100 ml. |
Violation |
B |
eSMR |
1112888 |
11/07/2022 |
Order Conditions |
Enterococci Single Sample Maximum limit is 104 MPN/100 mL and reported value was 1298 MPN/100 mL at RSW-001. *** MMP Exempt Reason:Receiving water sample - discharger not the cause of exceedance. |
Accelerated monitoring and the next samples were within parameter. |
Violation |
B |
eSMR |
1112889 |
11/07/2022 |
Order Conditions |
Fecal Coliform Single Sample Maximum limit is 400 MPN/100 mL and reported value was 1600 MPN/100 mL at RSW-001. *** MMP Exempt Reason:Receiving water sample - discharger not the cause of exceedance. |
We went into accelerated monitoring and resampled 11/9/10/22 through 11/12/22 and the results were 2 MPN/ 100ml, <1.8 MPN/ 100ml, and 4 MPN/ 100 ml respectively. |
Violation |
B |
eSMR |
1109784 |
07/31/2022 |
CAT1 |
Biochemical Oxygen Demand (BOD) (5-day @ 20 Deg. C) Monthly Average (Mean) limit is 30.0 mg/L and reported value was 37.2 mg/L at EFF-001. |
The health of the digester has been addressed and is being closely monitored. |
Violation |
B |
eSMR |
1106738 |
06/30/2022 |
OEV |
Fecal Coliform 10% for 30 days limit is 10 % and reported value was 14 % at EFF-001. |
Brought in contractors to fix some valves to allow us to take a clarifier offline for scheduled cleaning. The digester caused excess solids, and overloaded the plant for the specific days. |
Violation |
B |
eSMR |
1103753 |
02/24/2022 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 ug/L and reported value was 2323 ug/L at EFF-001. |
Installed thermometers to monitor daily room temperature, clean and flushed system. |
Violation |
B |
eSMR |
1100526 |
11/04/2021 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 ug/L and reported value was 3510 ug/L at EFF-001. |
Upon arrival, equipment was reset and pumps put back into normal operation. Once everything was operational, the SBS was quickly restored. |
Violation |
B |
eSMR |
1100523 |
11/01/2021 |
OEV |
Enterococci Instantaneous Maximum limit is 104 MPN/100 mL and reported value was 238 MPN/100 mL at RSW-001. *** MMP Exempt Reason:Receiving water sample - discharger not the cause of exceedance. |
No corrective action. Re-sample ocean every 24 hours. Also, along with ocean sample, grab a sample of plant effluent to compare ocean and plant results and show plant not the cause of the high enterococcus results in the ocean. |
Violation |
B |
eSMR |
1101212 |
11/01/2021 |
OEV |
Fecal Coliform Single Sample Maximum limit is 1600 MPN/100 mL and reported value was 400 MPN/100 mL at RSW-001. *** MMP Exempt Reason:Receiving water sample - discharger not the cause of exceedance. |
Accelerated monitoring was started on Friday for fecal coliform, within the required 24-hour accelerated monitoring requirement. |
Violation |
B |
eSMR |
1101220 |
10/25/2021 |
OEV |
Fecal Coliform Single Sample Maximum limit is 400 MPN/100 mL and reported value was 1600 MPN/100 mL at RSW-001. *** MMP Exempt Reason:Receiving water sample - discharger not the cause of exceedance. |
Accelerated monitoring was started on Friday for fecal coliform, within the required 24-hour accelerated monitoring requirement. |
Violation |
B |
eSMR |
1095934 |
07/24/2021 |
CAT1 |
Settleable Solids Instantaneous Maximum limit is 3.0 ml/L and reported value was 4.0 ml/L at EFF-001. |
Upon inspection, staff observed the mechanical sampler suction tube was laying on the floor of the effluent chamber when the high SS grab sample was collected. With the suction tube laying on the floor of the chamber, the mechanical sampler must have vacuumed up some solids resulting in the high recorded value. After this observation, the settleable solids grab sample has been taken directly from the effluent rather than through a mechanical sample device.
In addition to sampling for settleable solids directly from effluent, staff reset the mechanical sampler suction tube so it is suspended in the effluent.
|
Violation |
B |
eSMR |
1101211 |
07/15/2021 |
DMON |
It appears the gap in continuous monitoring was due to a computer update. The update automatically restarted the primary operations computer at about 3:15 AM. After the computer restarted, it did not activate the SCADA system. At 6:55 AM an operator logged onto the computer and started SCADA, thus starting continuous monitoring logging again. |
We are making every effort to correct this problem and have engaged a SCADA integrator to improve data logging redundancy and assure there is logging consistency throughout the SCADA system. |
Violation |
B |
eSMR |
1095933 |
07/15/2021 |
DMON |
It appears the gap in continuous monitoring was due to a computer update. The update automatically restarted the primary operations computer at about 3:15 AM. After the computer restarted, it did not activate the SCADA system. At 6:55 AM an operator logged onto the computer and started SCADA, thus starting continuous monitoring logging again. |
We are making every effort to correct this problem and have engaged a SCADA integrator to improve data logging redundancy and assure there is logging consistency throughout the SCADA system. |
Violation |
B |
eSMR |
1092649 |
06/13/2021 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 ug/L and reported value was 4266 ug/L at EFF-001. |
The on-call operator called a second operator, and both drove to the plant. The first operator that arrived at the plant reset the pumps and brought C-water pumps online. After resetting the carrier water systems and the SBS residual was restored, the operators checked Plant operations and reviewed the SBS residual information. The operators responded quickly and appropriately. The quick response minimized the time the carrier water system was offline, and SBS residual was restored within minutes. |
Violation |
B |
eSMR |
1092650 |
05/13/2021 |
DMON |
On May 13, 2021, during a planned training exercise, there was a lapse in continuous monitoring data from about 10:30 to 11:15 AM. the main operations area SCADA system was not powered during this period and the backup power supplies didnt power the system as expected. |
After seeing the operations room SCADA was not working as expected, staff brought utility power online and performed troubleshooting on the SCADA system. SCADA and continuous monitoring were restored at about 11:15 AM. Staff replaced backup power supplies for the SCADA system |
Violation |
B |
eSMR |
1101213 |
05/13/2021 |
DMON |
On May 13, 2021, during a planned training exercise, there was a lapse in continuous monitoring data from about 10:30 to 11:15 AM. the main operations area SCADA system was not powered during this period and the backup power supplies didn't power the system as expected. |
After seeing the operations room SCADA was not working as expected, staff brought utility power online and performed troubleshooting on the SCADA system. SCADA and continuous monitoring were restored at about 11:15 AM. Staff replaced backup power supplies for the SCADA system |
Violation |
B |
eSMR |
1084830 |
12/28/2020 |
OEV |
Enterococci Single Sample Maximum limit is 104 MPN/100 mL and reported value was 111 MPN/100 mL at RSW-001. *** MMP Exempt Reason:This is a receiving water limitation violation, not effluent an effluent limitation violation. Also note that the facility also monitors effluent enterococci and those results are much lower than these receiving water sample results. |
Effluent sample results from treated wastewater effluent discharged to the ocean are much lower than the receiving water sample results and indicate the high enterococcus density results must have been from another source. |
Violation |
B |
eSMR |
1084834 |
12/14/2020 |
OEV |
Enterococci Single Sample Maximum limit is 104 MPN/100 mL and reported value was 164 MPN/100 mL at RSW-001. *** MMP Exempt Reason:This is a receiving water limitation violation, not effluent an effluent limitation violation. Also note that the facility also monitors effluent enterococci and those results are much lower than these receiving water sample results. |
Effluent enterococci sample results from treated wastewater effluent discharged to the ocean are much lower than the receiving water sample results and indicate the high enterococcus density results must have been from another source. |
Violation |
B |
eSMR |
1084832 |
12/14/2020 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 ug/L and reported value was 3716 ug/L at EFF-001. |
To reduce potential problems at the plant associated with a utility power failure, staff ordered and installed new batteries in equipment back-up power supplies. These back-up power supplies can help maintain equipment settings during brief power failures. |
Violation |
B |
eSMR |
1084831 |
11/17/2020 |
OEV |
Enterococci Single Sample Maximum limit is 104 MPN/100 mL and reported value was 271 MPN/100 mL at RSW-001. *** MMP Exempt Reason:This is a receiving water limitation violation, not effluent an effluent limitation violation. Also note that the facility also monitors effluent enterococci and those results are much lower than these receiving water sample results. |
November 17 effluent sample results from treated wastewater effluent discharged to the ocean are much lower than the receiving water sample results and indicate the high enterococcus density results must have been from another source. |
Violation |
B |
eSMR |
1084836 |
11/16/2020 |
OEV |
Enterococci Single Sample Maximum limit is 104 MPN/100 mL and reported value was 111 MPN/100 mL at RSW-001. *** MMP Exempt Reason:This is a receiving water limitation violation, not effluent an effluent limitation violation. Also note that the facility also monitors effluent enterococci and those results are much lower than these receiving water sample results. |
November 16 effluent sample results from treated wastewater effluent discharged to the ocean are much lower than the receiving water sample results and indicate the high enterococcus density results must have been from another source. |
Violation |
B |
eSMR |
1084833 |
10/31/2020 |
OEV |
Fecal Coliform 10% for 30 days limit is 10 % and reported value was 15 % at EFF-001. |
In addition to stabilizing MBR filtrate flow to the plant effluent, staff increased flow to the MBR to boost the overall filtrate flow and improve the plant¿s effluent quality. Also, as a precaution, an off-line secondary clarifier was placed into service so the secondary clarifier that had been online could be cleaned. The primary clarifier that was online was also swapped out for a clean primary clarifier. In addition, the chlorine dose rate was increased to intensify disinfection through the chlorine contact tank. As an added step, the chlorine contact basin was thoroughly cleaned. Going forward, the plant operators will continue to regularly discuss and evaluate lab results for a variety of treatment processes with the goal of staying in compliance with the fecal coliform limits. |
Violation |
B |
eSMR |
1084829 |
10/31/2020 |
OEV |
Fecal Coliform 30-Day Median limit is 14 MPN/100 mL and reported value was 17 MPN/100 mL at EFF-001. |
In addition to stabilizing filtrate flow to the plant effluent, staff increased flow to the MBR to boost the overall filtrate flow and improve the plant¿s effluent quality. Also, as a precaution, an off-line secondary clarifier was placed into service so the secondary clarifier that had been online could be cleaned. The primary clarifier that was online was also swapped out for a clean primary clarifier. In addition, the chlorine dose rate was increased to intensify disinfection through the chlorine contact tank. As an added step, the chlorine contact basin was thoroughly cleaned. Going forward, the plant operators will continue to regularly discuss and evaluate lab results for a variety of treatment processes with the goal of staying in compliance with the fecal coliform limits. |
Violation |
B |
eSMR |
1084835 |
10/04/2020 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 ug/L and reported value was 3600 ug/L at EFF-001. |
A faulty backpressure valve was replaced with a new one, and the backpressure PSI was set for the application. The pump was tested and works as expected. |
Violation |
B |
eSMR |
1080728 |
08/06/2020 |
OEV |
Fecal Coliform 10% for 30 days limit is 10 % and reported value was 15 % at EFF-001. |
Collect samples directly from the Effluent.
Perform daily check on chlorine flash mixer shaft.
Regularly check sludge pump operations and pump routine/times.
Average three sludge depth samples per clarifier per day.
|
Violation |
U |
eSMR |
1080729 |
07/26/2020 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 ug/L and reported value was 3000 ug/L at EFF-001. |
We will conduct periodic training for power interruptions, equipment resets, how to check on SCADA for faulted equipment, what equipment should be brought online first, and what equipment is likely to be affected by a utility power interruption. |
Violation |
U |
eSMR |
1077664 |
05/31/2020 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 ug/L and reported value was 3705 ug/L at EFF-001. |
Train for power interruptions, equipment resets, how to check on SCADA for faulted equipment, what equipment should be brought online first, and what equipment is likely to be affected by a utility power interruption. |
Violation |
U |
eSMR |
1077667 |
05/15/2020 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 ug/L and reported value was 3410 ug/L at EFF-001. |
Regularly Inspect pumps and observe pump and check valves for proper operation. |
Violation |
U |
eSMR |
1077665 |
04/27/2020 |
OEV |
Enterococci Single Sample Maximum limit is 104 MPN/100 mL and reported value was 254 MPN/100 mL at RSW-001. *** MMP Exempt Reason:This is a receiving water limitation violation, not effluent an effluent limitation violation. Also note that the facility also monitors effluent enterococci and those results are much lower than these receiving water sample results. |
Conducted repeat sampling with sample results within permit limits |
Violation |
B |
eSMR |
1077666 |
04/04/2020 |
CAT1 |
Settleable Solids Instantaneous Maximum limit is 3.0 ml/L and reported value was 7.0 ml/L at EFF-001. |
In the future, bring online other available clarifiers to slow down flow and settle solids out of the liquid stream. |
Violation |
U |
eSMR |
1073454 |
02/03/2020 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 ug/L and reported value was 3170 ug/L at EFF-001. |
Temperature in the SBS chemical storage building has been adjusted so SBS crystals don't form in piping and storage tanks during cold periods. |
Violation |
U |
eSMR |
1073455 |
01/16/2020 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 ug/L and reported value was 3250 ug/L at EFF-001. |
Upon investigation it was determined that the Y-strainer from the SBS chemical tanks had plugged.... The Y-strainer was cleaned, and [SBS] residual was regained at 4:53 am. |
Violation |
B |
eSMR |
1073453 |
01/16/2020 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 1800 ug/L and reported value was 3550 ug/L at EFF-001. |
The steps we have taken to ensure this does not repeat itself is we have placed the cleaning of the [SBS] y-strainer in our maintenance management system so that a work order will be issued each month. We do rotate duty and standby pumps on a regular basis and it should be noted that the last time the standby pump was operated in worked well. |
Violation |
B |
eSMR |
1066729 |
09/06/2019 |
CAT2 |
Copper, Total Recoverable Instantaneous Maximum limit is 840 ug/L and reported value was 1080 ug/L at EFF-001. |
As part of Table E-4 in the permit, accelerated monitoring was initiated. An additional composite sample was taken on November 6, 2019 and on November 15, 2019. The result of 840 ug/L was received by the contract lab on November 1st and read on November 2nd.
It should be noted that on September 5th and September 7th, the results for Copper, Total Recoverable were a non-detect (ND) and a 6.02 ug/L respectively. The sample result taken on November 6th was a 9.7 ug/L, all showing the treatment plant is well within permit requirements.
|
Violation |
U |
eSMR |
1066731 |
09/05/2019 |
CAT1 |
Oil and Grease Instantaneous Maximum limit is 75 mg/L and reported value was 93.5 mg/L at EFF-001. |
As part of Table E-4 in the permit, accelerated monitoring was initiated. An additional grab sample was taken on November 6, 2019 and on November 15, 2019. The result of 93.5 mg/L was received by the contract lab on November 1st and read on November 2nd.
It should be noted that the Oil and Grease result from the sample taken on September 6th was a non-detect (ND) and the result on September 7th was 21.0 mg/L. The sample taken on November 6th was also a ND showing the treatment facility is well within permit requirements. This result appears to be an outlier. We will continue to review our sampling protocols to ensure proper collection and handling of samples.
|
Violation |
U |
eSMR |