| Violation ID |
Occurred Date |
Violation Type |
(-) Violation Description |
Corrective Action |
Status |
Classification |
Source |
| 1149409 |
10/08/2025 |
OEV |
Total Coliform 7-Day Median limit is 23 MPN/100 mL and reported value was 34 MPN/100 mL at M-001A. |
Upon identifying the exceedance and associated operational conditions, the district implemented immediate corrective actions to stabilize treatment performance and restore regulatory compliance.
Aeration System Restoration
Operators promptly placed Blower 3 into service and adjusted its output based on real-time dissolved oxygen demand. With manufacturer technical support, staff diagnosed and repaired the malfunctioning units the following day. Blower 1 received a replacement input card, and the loose electrical connection on Blower 2's variable-speed drive was secured and verified. Both blowers were fully restored to automated operation, returning the system to normal aeration redundancy.
Suspension of Digester Cleaning Activities
Recognizing that intermittent digester pumping was contributing to increased system loading during a period of reduced aeration capacity, staff suspended the digester cleaning operation. This action prevented additional organic loading until full aeration functionality and stable process conditions were re-established.
Laboratory Data Entry and Reporting
All coliform analytical results were entered, verified, and used to calculate the running median once delays were identified. Staff reviewed the findings with operations personnel to ensure alignment with corrective actions. Normal laboratory reporting resumed once director returned.
Regulatory Notification
Required notifications were completed in accordance with regulatory requirements. Supporting operational and laboratory records were compiled and submitted in this report. Drew Friedrich of the Central Coast Regional Water Quality Control Board was notified promptly upon confirmation of the violation.
These corrective measures restored system performance and prevented further compliance impacts. |
Violation |
U |
eSMR |
| 1147248 |
08/14/2025 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 5600 ug/L and reported value was 6230 ug/L at M-001A. |
Equipment calibrated, see attached causation. |
Violation |
U |
eSMR |
| 1147247 |
08/14/2025 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 5600 ug/L and reported value was 6660 ug/L at M-001A. |
Equipment calibrated, see attached causation. |
Violation |
U |
eSMR |
| 1147246 |
08/14/2025 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 5600 ug/L and reported value was 6680 ug/L at M-001A. |
Equipment calibrated, see attached causation. |
Violation |
U |
eSMR |
| 1147249 |
08/14/2025 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 5600 ug/L and reported value was 6730 ug/L at M-001A. |
Equipment calibrated, see attached causation. |
Violation |
U |
eSMR |
| 1147252 |
08/14/2025 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 5600 ug/L and reported value was 6970 ug/L at M-001A. |
Equipment calibrated, see attached causation. |
Violation |
U |
eSMR |
| 1147250 |
08/14/2025 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 5600 ug/L and reported value was 7.870 ug/L at M-001A. |
Equipment calibrated, see attached causation. |
Violation |
U |
eSMR |
| 1147251 |
08/14/2025 |
CAT2 |
Chlorine, Total Residual Instantaneous Maximum limit is 5600 ug/L and reported value was 8220 ug/L at M-001A. |
Equipment calibrated, see attached causation. |
Violation |
U |
eSMR |
| 1131163 |
07/27/2024 |
OEV |
Total Coliform 7-Day Average (Mean) limit is 23 MPN/100 mL and reported value was 33 MPN/100 mL at M-001A. |
Plant operation had returned to normal in the previous days to the violation and the coliform results were unexpected.
The Coliform sample collected on Monday July 29, 2024 has the district back in compliance. |
Violation |
U |
eSMR |
| 1105576 |
05/01/2022 |
OEV |
Total Coliform Instantaneous Maximum limit is 2300 MPN/100 mL and reported value was 16000 MPN/100 mL at M-001A. |
The operator on duty who performed the analysis was retrained on the proper procedure. |
Violation |
B |
eSMR |
| 1099036 |
12/28/2021 |
OEV |
Total Coliform 7-Day Median limit is 23 MPN/100 mL and reported value was 31 MPN/100 mL at M-001A. |
It was believed there was a sampling protocol error. The operators were retrained on the proper sampling technique. |
Violation |
B |
eSMR |
|
Report displays most recent five years of violations. Refer to the Interactive Violation Report for more data.
|