Violation ID |
Occurred Date |
Violation Type |
(-) Violation Description |
Corrective Action |
Status |
Classification |
Source |
1117947 |
01/01/2023 |
DMON |
Discharger failed to monitor influent flow, violating WDR R6V-99-033 section: MRP I.A.1-4. Unable to report influent flow due to power failure. Power failure erased the monitoring program and the calibration of the flow meter. January 1, 2023 – March 31, 2023 |
Scheduling of instrument technician is pending. |
Violation |
B |
Report |
1105680 |
11/30/2021 |
Deficient Reporting |
Failed to provide results for several parameters related to effluent quality Violated Board Order No.R6V-99-033MRP Section I.B1,2. |
Discharger could not propose any corrective action at the time. (Results submitted on 04/15/2022) |
Violation |
B |
Report |
1092758 |
06/30/2021 |
Deficient Reporting |
Failure to provide results for 2nd Qtr. effluent monitoring. Analytical values were not received with the report for May or June 2021, Violated Board Order No. R6V-1999-033 Section I.B.1 & 2 |
As soon as the lab data is received, Edwards AFB will submit the second quarter report addendum that includes both the May and June 2021 analytical. May or June has not been released by Babcock Laboratories due to a billing dispute between Babcock Laboratories and National O & M. As soon as the data is received, Edwards AFB will submit the second quarter report addendum that includes both May and June 2021 analytical results. |
Violation |
B |
Report |
1085816 |
12/31/2020 |
DMON |
Failed to report several parameters for BOD, dissolved oxygen, MBAS, and pH values. Violating Board Order 6-99-033 3 I. Monitoring B. Facility, Effluent Monitoring |
Edwards AFB Contracting Office is working with National O &M to address this issue so that the analytical data can be received.
As soon as Edwards AFB has the data, the quarterly report will be revised and resubmitted. Exact schedule unknown at this
time. The contract lab has a legal requirement to notify us if analytical results exceeded limits; no notification was made. |
Violation |
B |
Report |
1085821 |
08/19/2020 |
CAT1 |
Iron, Total Single Sample Maximum limit is 300 ug/L and reported value was 730 ug/L. |
Discharger did not propose or identify any corrective actions to be taken. |
Violation |
B |
Report |
1085820 |
08/19/2020 |
CAT2 |
Arsenic, Total Single Sample Maximum limit is 10 ug/L and reported value was 13 ug/L. |
Discharger did not propose or identify any corrective actions to be taken. |
Violation |
B |
Report |
1071511 |
01/16/2020 |
Order Conditions |
Failed to comply with Amendment to the MRP R6V-99-033 dated October 9, 2019. |
Discharger will use GeoTracker to upload future reports according to Amendment to MRP R6V-99-033 Dated October 9, 2019 |
Violation |
B |
Report |
Report displays most recent five years of violations. Refer to the Interactive Violation Report for more data.
|